Data Sheet
65
Rev. 1.00
2017-07-31
TLE9262BQXV33
High-Side Switch
9.3
Electrical Characteristics
Table 15 Electrical Characteristics
V
S
= 5.5 V to 28 V;
T
j
= -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Parameter
Symbol
Values
Unit Note or
Test Condition
Number
Min.
Typ.
Max.
Output HS1, HS2, HS3, HS4
Static Drain-Source ON
Resistance HS1...HS4
R
ON,HS25
–
7
10
Ω
I
ds
= 60mA,
T
j
< 25°C
P_9.3.1
Static Drain-Source ON
Resistance HS1...HS4
R
ON,HS150
–
11.5
16
Ω
I
ds
= 60mA,
T
j
< 150
°
C
P_9.3.2
Leakage Current HSx / per
channel
I
leak,HS
–
–
2
µA
1)
0 V <
V
HSx
<
V
SHS
;
T
j
< 85°C
P_9.3.11
Output Slew Rate (rising)
SR
raise,HS
0.8
–
2.5
V/µs
1)
20 to 80%
V
SHS
= 6 to 18V
R
L
= 220
Ω
1) Not subject to production test, specified by design.
P_9.3.3
Output Slew Rate (falling)
SR
fall,HS
-2.5
–
-0.8
V/µs
1)
80 to 20%
V
SHS
= 6 to 18V
R
L
= 220
Ω
P_9.3.4
Switch-on time HSx
t
ON,HS
3
–
30
µs
CSN = HIGH to
0.8*VSHS;
R
L
= 220
Ω
;
V
SHS
= 6 to 18V
P_9.3.5
Switch-off time HSx
t
OFF,HS
3
–
30
µs
CSN = HIGH to
0.2*VSHS;
R
L
= 220
Ω
;
V
SHS
= 6 to 18V
P_9.3.6
Short Circuit Shutdown
Current
I
SD,HS
150
245
300
mA
V
SHS
= 6 to 20V,
hysteresis
included
P_9.3.7
Short Circuit Shutdown
Filter Time
t
SD,HS
12
16
20
µs
2)
,
3)
2) Not subject to production test, tolerance defined by internal oscillator tolerance.
3) Configure proper minimum PWM settings for reliable detection of overcurrent and open load measurement (see also
Chapter 9.2.5
).
P_9.3.8
Open Load Detection
Current
I
OL,HS
0.4
–
3
mA
hysteresis
included
P_9.3.9
Open Load Detection
hysteresis
I
OL,HS,hys
0.05
0.45
1.0
mA
1)
P_9.3.14
Open Load Detection Filter
Time
t
OL,HS
50
64
80
µs
2)
,
3)
P_9.3.10