TLE9262BQXV33
General Product Characteristics
Data Sheet
15
Rev. 1.00, 2017-07-31
4.2
Functional Range
Note: Within the functional range the IC operates as described in the circuit description. The electrical
characteristics are specified within the conditions given in the related electrical characteristics table.
Device Behavior Outside of Specified Functional Range:
•
28V
< V
S,func
< 40V: Device will still be functional including the state machine; the specified electrical
characteristics might not be ensured anymore. The regulators VCC1/2/3 are working properly, however, a
thermal shutdown might occur due to high power dissipation. HSx switches might be turned OFF depending
on VSHS_OV configurations. The specified SPI communication speed is ensured; the absolute maximum
ratings are not violated, however the device is not intended for continuous operation of VS >28V. The device
operation at high junction temperatures for long periods might reduce the operating life time;
•
18V <
V
S,LIN
<28V: The LIN transceiver is still functional. However, the communication might fail due to out-of-
LIN-spec operation;
•
V
SHS,UVD
<
V
S,LIN
< 6V: The LIN transceiver is still functional. However, the communication might fail due to out-
of-LIN-spec operation;
•
V
CAN
< 4.75V: The undervoltage bit
VCAN_UV
will be set in the SPI register
BUS_STAT_1
and the transmitter
will be disabled as long as the UV condition is present;
•
5.25V
< V
CAN
< 5.50V: CAN transceiver still functional. However, the communication might fail due to out-of-
spec operation;
•
V
POR,f
< VS < 5.5V: Device will still be functional; the specified electrical characteristics might not be ensured
anymore.
– The voltage regulators will enter the low-drop operation mode
(applies for VCC3 only if bit
VCC3_VS_ UV_OFF
is set),
– A VCC1_UV reset could be triggered depending on the Vrtx settings,
– The LIN transmitter will be disabled if V
SHS,UVD
is reached,
– HSx switch behavior will depend on the respective configuration:
-
HS_UV_SD_EN
= ‘0’ (default): HSx will be turned OFF for VSHS < VSHS_UV and will stay OFF;
-
HS_UV_SD_EN
= ‘1’: HSx stays on as long as possible. An unwanted overcurrent shut down may occur.
OC shut down bit set and the respective HSx switch will stay OFF;
– FOx outputs will remain ON if they were enabled before VS > 5.5V,
– The specified SPI communication speed is ensured.
Table 2
Functional Range
Parameter
Symbol
Values
Unit
Note /
Test Condition
Number
Min.
Typ.
Max.
Supply Voltage
V
S,func
V
POR
–
28
V
1)
V
POR
see
section
Chapter 15.10
1) Including Power-On Reset, Over- and Undervoltage Protection
P_4.2.1
LIN Bus Voltage
V
S,LIN,func
6
–
18
V
2)
2) Parameter Specification according to LIN 2.2 standard
P_4.2.2
CAN Supply Voltage
V
CAN,func
4.75
–
5.25
V
–
P_4.2.3
SPI frequency
f
SPI
–
–
4
MHz
see
Chapter 16.7
for f
SPI,max
P_4.2.4
Junction Temperature
T
j
-40
–
150
°C
–
P_4.2.5