Document Number: 002-10634 Rev. *J
Page
180 of 307
S6J3350 Series
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Max
Serial clock
"H" pulse width
t
SHSL
SCK0 to SCK4,
SCK8 to SCK12
Slave
Mode
(CL = 20pF,
I
OL
= -5mA,
I
OH
= 5mA)
4t
CLK_LCPnA
*1
-
ns
-
SCK16 to SCK17
4t
CLK_COMP
-
ns
Serial clock
"L" pulse width
t
SLSH
SCK0 to SCK4,
SCK8 to SCK12
4t
CLK_LCPnA
*1
-
ns
SCK16 to SCK17
4t
CLK_COMP
-
ns
SCK ↓→ SOT
delay time
t
SLOVE
SCK0 to SCK4,
SCK8 to SCK12,
SCK16 to SCK17
SOT0 to SOT4,
SOT8 to SOT12,
SOT16 to SOT17
-
40
ns
Valid SIN → SCK ↑
setup time
t
IVSHE
SCK0 to SCK4,
SCK8 to SCK12,
SCK16 to SCK17
SIN0 to SIN4,
SIN8 to SIN12,
SIN16 to SIN17
10
-
ns
SCK ↑ → Valid SIN
hold time
t
SHIXE
10
-
ns
SCK falling time
t
F
SCK0 to SCK4,
SCK8 to SCK12,
SCK16 to SCK17
-
5
ns
SCK rising time
t
R
SCK0 to SCK4,
SCK8 to SCK12,
SCK16 to SCK17
-
5
ns
*1: n = 0:ch.0 to ch.4, n = 1:ch.8 to ch.12
Notes:
−
This table provides the alternate current standard for CLK synchronous mode.
−
CL is the load capability value connected to the pin at the test time.
−
The maximum baud rate is limited by the internal operating clock used and other parameters.