Document Number: 002-10634 Rev. *J
Page
236 of 307
S6J3350 Series
VCC12 and RSTX Sequence
(T
A
: Recommended operating conditions, VSS = 0.0 V)
Parameter
Symbol
Pin Name
Conditions
Value
Unit
Remarks
Min
Max
RSTX -> VCC12 fall
interval time
t
FV12RST
VCC12,
RSTX
-
5
-
us
−
VCC12 -> RSTX
rise
interval time
t
RV12RST
VCC12,
RSTX
35
-
us
−
Note:
−
If the sequence given in VCC5 and VCC12 sequence" cannot be applied, this sequence can be applied.
−
VDLAT VRDLAT, VRDLAT and VRHYS are referred to "
Low Voltage Detection (External Voltage)
".
VIL9 and VIH9 is referred to "
".
−
This sequence is applied in case of VCC12 power on/off and assertion of RSTX is controlled by application.
−
This sequence is applied under the condition VCC5 > VDLAT and PSC_1 = H.
VCC12
RSTX
t
RV12RST
V
RDLAT
+V
RHYS
V
RDLAT
VCC5
PSC_1
H
t
FV12RST
V
IL9
V
IH9
VCC5 > V
DLAT
*1