Industrex M43ic / M43icN
page 33
01/2013 TK
control panel
temp. probe DRY
Output Extension Board
temp. probe FIX
sensorbar
IIC-distribution board
PDB MF 800
+
CPU
DRYER.....RED
FIX............BLUE
DEV..........YELLOW
8. I2C-BUS SYSTEM
Probes positioned under solution levels precisely monitor all solution tank temperatures.
These temperature probes are continuously supplying information to the microprocessor
on actual solution temperatures within the tanks. The microprocessor then compares
these actual temperatures to the required programmed ”set” temperatures and controls
the relevant heaters/cooling systems accordingly.
Temp.-probe
Developer Temp.
Heating/Cooling
Fix Temp.
Heating/Cooling
Dry
Heating
Sensorbar
Incomming plate-area
Replenishment
Bus-System
Measurement
Action
NOTE:To transfer this information, a BUS-SYTEM is installed.
OVERVIEW:
9. VENTILATION
To prevent cristalization and humidity inside the filmprocessor a ventilation divice is fitted
to processor. It is recommended to connect the below mentioned tube to an external
exhaust device to prevent any possible problems.
WARNING: To install such a external exhaust device, is allowed for qualified
Service personnel only.
tube with cover lid
ventilations holes
temp. probe DEV
Summary of Contents for M43ic
Page 1: ...INSTRUCTION MANUAL 04 2011 TK NDT FILM PROCESSOR Industrex M43ic M43icN AT800 v2 8r09p and up ...
Page 3: ...Input speed DEV time Cycle time KODAKIndustrexM43ic Industrex M43ic M43icN ...
Page 49: ...page 43 01 2013 TK Industrex M43ic M43icN NOTES ...
Page 50: ...page 44 01 2013 TK Industrex M43ic M43icN NOTES ...
Page 51: ...page 45 01 2013 TK Industrex M43ic M43icN NOTES ...