Hydraulic fluid filter G220 G420
e
Accumulator drain valve
X
Hydraulic fluid filter
Y
Filter bowl
Replace the filters (Z) of the hydraulic fluid filters (X). A different number of
hydraulic fluid filters (X) may be installed, depending on the version. Unscrew
filter bowl (Y), remove contaminated hydraulic fluid (oil sump) and used filter
(Z) from the filter bowl (Y) and dispose of them according to environmental
regulations.
4.
Only filters with retained particle sizes described in the fluid
plans must be used.
Maintenance Summary - 4.000 Operating hours