iDrive2 inverters Function Parameters
30
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
automatically.
P01.20
Hibernation
restore delay
time
Sets the hibernation delay time. When the running
frequency of the inverter is lower than the lower limit
one, the inverter will pause to stand by.
When the set frequency is above the lower limit for
longer than time set by P01.20, the inverter will run
automatically.
Note:
The time is the total value when the set frequency
is above the lower limit one.
Setting range: 0.0~3600.0s (valid when P01.19=2)
0.0s
○
P01.21
Restart after
power off
This function can enable the inverter start or not after the
power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the inverter will
run automatically after waiting for the time defined by
P01.22.
0
○
P01.22
Restart delay
time after
power off
The function sets the delay time before the automatic
running of the inverter after power up.
Setting range: 0.0~3600.0s (valid when P01.21=1)
1.0s
○
P01.23
Start delay
time
The function determines the brake release after the
running command is given, and the inverter is in a
stand-by state and wait for the delay time set by P01.23
Setting range: 0.0~60.0s
0.0s
○
P01.24
Delay of the
stopping
speed
Setting range: 0.0~100.0 s
0.0s
○
P02 Group Motor 1
P02.01
Asynchronou
s motor rated
power
0.1~3000.0kW
Depend
on model
◎