6
STVZSkW ed 09/08
VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
Primary circuit (boiler circuit).
The primary circuit, with relative control and safety devices,
is started
every time there is a central heating or domestic
hot water request.
Operation
(see hydraulic diagram).
The heat contained in the combustion products is absorbed
by the pipes of the water-gas primary heat exchanger with
coil (13) which then gives the heat up to the water made to
circulate inside the boiler pump (28).
The water is introduced directly into the system or can be
diverted inside the storage tank coil (2).
This depends on the position of the motorised 3-way valve
H
ead (kP
a)
Flow rate Litres/h
A = Head available to the system on the third speed with by-pass excluded (adjustment screws tightened fully home)
B = Head available to the system on the second speed with by-pass excluded (adjustment screws tightened fully home)
C = Head available to the system on the first speed with by-pass excluded (adjustment screws tightened fully home)
D = Total head available to the plant on the third speed (screws tightened by 1.5 revs with respect to the completely loose adjustment screws).
E = Total head available to the plant on the second speed (screws tightened by 1.5 revs with respect to the completely loose adjustment screws).
F = Total head available to the plant on the first speed (screws tightened by 1.5 revs with respect to the completely loose adjustment screws).
H
ead (m H
2
O)
VICTRIX ZEUS Superior 26 kW I
H
ead (kP
a)
Flow rate Litres/h
H
ead (m H
2
O)
VICTRIX ZEUS Superior 32 kW I
A
C
(32), which depending on request, allows flow towards the
system flow (M) and return (R) pipes or causes diversion
towards the coil (2).
Head-flow rate graphics.
The progress of the curve that represents the flow rate-head ratio
available to the system, depends on the functioning speed of the
pump and adjustment of the system by-pass which, according
to the position, allows to set greater or less head on he system.
The graphs below show the characteristic curves.
E
F
A
C
B
F
E
B
D
D
Summary of Contents for VICTRIX Superior 32 kW X