10
STVZSkW ed 09/08
VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
GIM Multifunction Integrated Unit.
3
2
1
4
5
9
8
14
13
11
7
6
12
10
15
Before replacing the various components present on the GIM
unit, the water present inside the primary circuit must be
drained by opening the system draining valve (15).
Before draining, ensure that the system filling valve is closed.
Three-way valve cartridge replacement.
To replace the 3-way cartridge (1) slide the blocking clip out
(2) and extract the small electric motor (3) and then unscrew
the screw fasteners (4) that fix the cartridge (1) to the com-
posite body (6).
N.B.:
when re-mounting the cartridge, pay particular atten-
tion to correctly insert the two small sheet steel reinforcement
plates (5).
Pump motor replacement.
To replace the pump body, remove the 4 screws (8) that fix the
motor (7) to the composite body (6).
Replacement of the automatic air vent valve.
To replace the air vent valve, the relative blocking clip must
be removed and the valve extracted (9) paying attention not
to damage the relative OR gasket.
N.B.:
when re-mounting the air vent valve, pay particular
attention to insert the relative OR gasket correctly.
By-pass cartridge replacement.
To replace the by-pass cartridge, loosen the relevant 2 screws
(12) that fix the cartridge body (11) to the flow manifold
(10).
N.B.:
when re-mounting the by-pass cartridge body pay par-
ticular attention not to damage the gasket.
3 bar safety valve replacement.
To replace the 3 bar safety valve (13) slide the relative blocking
clip out.
N.B.:
when re-mounting the 3 bar valve, pay particular atten-
tion to insert the relative OR gasket correctly.
System pressure switch replacement.
To replace the system pressure switch (14) the relative blocking
clip must be removed.
N.B.:
when re-mounting the system pressure switch, pay par-
ticular attention to insert the relative OR gasket correctly.