VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
ERROR 31
Loss of remote control communication
31
The Remote Control is connected correctly
.
N.B.: it is possible to use only remote controls supplied by Immergas
(CAR or Super CAR).
No
Check the connection between P.C.B. (clamps 42-43) and remote control
(IN+ and IN-) carried out respecting the polarity and using a dedicated
line to prevent interference.
Yes
Replace the remote control. If the anomaly persists, replace the P.C.B.
ERROR 37
Low power supply voltage
37
The boiler power supply voltage exceeds 190 VDC.
No
Restore the correct electric power of the appliance (230 VDC ±10%).
Yes
The electric power supply connection wires and relative external
fuses are integral.
No
Restore the electric connection/replace the cables/external fuses.
Yes
Replace the P.C.B.