45
STVZSkW ed 09/08
VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
Combustion parameters.
G20
G30
G31
Supply pressure
mbar (mm c.a.)
20 (204)
29 (296)
37 (377)
VICTRIX ZEUS Superior 26 kW I
Gas nozzle diameter
mm
5.70
4.10
4.10
Flue flow rate at max heat output
kg/h
43
39
43
Flue flow rate at min heat output
kg/h
8
7
8
CO
2
at Q. Nom./Min.
%
9.40 / 8.90
12.00 / 11.80
10.60 / 10.20
CO at 0% of O
2
at Nom. Q./Min.
ppm
200 / 7
670 / 11
270 / 7
NO
X
at 0% of O
2
at Nom. Q./Min..
mg/kWh
50 / 25
188 / 68
69 / 41
Flue temperature at nominal output
°C
78
86
79
Flue temperature at minimum output
°C
73
82
75
VICTRIX ZEUS Superior 32 kW I
Gas nozzle diameter
mm
WITHOUT
6.00
6.00
Flue flow rate at max heat output
kg/h
52
47
53
Flue flow rate at min heat output
kg/h
12
11
12
CO
2
at Q. Nom./Min.
%
9.40 / 8.90
12.30 / 11.90
10.50 / 10.30
CO at 0% of O
2
at Nom. Q./Min.
ppm
206 / 9
640 / 8
190 / 8
NO
X
at 0% of O
2
at Nom. Q./Min.
mg/kWh
50 / 25
188 / 68
69 / 41
Flue temperature at nominal output
°C
73
82
74
Flue temperature at minimum output
°C
64
72
66
Summary of Contents for VICTRIX Superior 32 kW X