82
INS
TALL
AT
O
RE
U
TENTE
MANU
TENT
O
RE
Average temperature table (47/55) average zones
Model:
Victrix Hybrid
Air/water heat pump: yes
Water/water heat pump: no
Brine/water heat pump: no
Low temperature heat pump: no
With additional central heating device: yes
Mixed central heating device with heat pump: yes
The parameters are declared for average temperature application, except for low temperature heat pumps. The parameters for low temperature heat
pumps are declared for low temperature application
The parameters are declared for average climatic conditions
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
Nominal
output
6
kW
Room central heating sea-
sonal energy efficiency
η
s
128
%
Central heating capacity declared with a partial load and indoor tempera-
ture equivalent to 20°C and outdoor temperature Tj
Central heating capacity declared with a partial load and indoor
temperature equivalent to 20°C and outdoor temperature Tj
T
j
= – 7 °C
Pdh
-
kW
T
j
= – 7 °C
COPd
-
–
T
j
= + 2 °C
Pdh
3,0
kW
T
j
= + 2 °C
COPd
3,19
–
T
j
= + 7 °C
Pdh
3,2
kW
T
j
= + 7 °C
COPd
4,52
–
T
j
= + 12 °C
Pdh
3,9
kW
T
j
= + 12 °C
COPd
6,42
–
T
j
= bivalent temperature
Pdh
3,0
kW
T
j
= bivalent temperature
COPd
3,19
–
T
j
= operating limit temperature
Pdh
2,5
kW
T
j
= operating limit
temperature
COPd
2,49
–
for air/water heat pumps: Tj = – 15 °C
(if TOL < – 20 °C)
Pdh
-
kW
for air/water heat pumps: Tj
= – 15 °C
(se TOL < – 20 °C)
COPd
-
–
Bivalent temperature
T
biv
2
°C
for air/water heat pumps:
operating limit temperature
TOL
- 3
°C
Central heating capacity cycle inter-
vals
Pcych
-
kW
Cycle intervals efficiency
COPcyc o
PERcyc
-
–
Degradation coefficient
Cdh
1,0
—
Water heating temperature
operating limit
WTOL
-
°C
Different mode of energy consumption from the active mode
Additional heating appliance
OFF mode
P
OFF
0,015
kW
Nominal heat output
Psup
24
kW
Thermostat mode off
P
TO
0,015
kW
Type of energy supply
voltage
gas
Standby mode
P
SB
0,015
kW
Guard heating mode
P
CK
0,000
kW
Other items
Capacity control
Variable
For air/water heat pum-
ps: nominal air output to
outside
—
1698
m
3
/h
Indoor/outdoor sound level
int. - est.
L
WA
48 - 59
dB
For water or brine/water heat
pumps: nominal flow of brine or
water, outdoor heat exchanger
—
-
m
3
/h
Annual energy consumption
Q
HE
3800
kWh o GJ
For mixed central heating appliances with a heat pump
Stated load profile
-
Water central heating
energy efficiency
η
wh
-
%
Daily electrical power consumption
Q
elec
-
kWh
Daily fuel consumption
Q
fuel
-
kWh
annual energy consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
Contact information
Immergas s.p.a via Cisa Ligure n.95