2.3 CONTROL PANEL.
41
Key:
1 - Main parameters switch with button to confirm and save data
2 - Left context button
3 - Right context button
4 - Display
2.4 OPERATION OVERVIEW.
Once the device has been powered, it goes into the status prior
to switch-off. Press the “Modo” (Mode) button to cyclically select
the desired mode amongst those available.
The current operating mode in use is displayed by the relative icon
at the bottom left corner (Fig. 41).
Also, depending on the system's configuration, the main screen
displays various information regarding the system, amongst which:
Status
Description
nn External temperature value (with external probe active)
Room heating request in progress
Comfort temperature operation
Economy temperature operation
Operation in manual mode
External probe enabled
Anomaly present
The temperature detected by the temperature is indicated at the
centre of the display on the control panel.
The lower part of the display shows the parameter that can be
changed (it varies according to the configuration). It is possible to
change the value by turning the main switch or using the ”Set Point
Zone” menu and pressing it to confirm the parameter change.
The values that can be found according to the configuration, are:
Parameter
Configuration (see Par 3.6)
Set room
Defines the room zone
temperature
Room control interface = P. Rem.
Set flow
Defines the system's flow
temperature to the zone
Room control interface = T.A.
External probe enabling = No
Flow offset
Changes the operation
curve of the external
probe
Room control interface = T.A.
External probe enabling = Yes
41
State
Description
DHW (Domestic hot water)
Central heating
Stand-by
Disabled
Disabled
Summer
Enabled
Disabled
Winter
Enabled
Enabled
12:34
We 8 Jan 2020
Mode
Menu
20.6
°C
Heating
Room Set 21.0°C
Zone
13°C
4
2
1
3