USE ONLY WITH A 250V FUSE

FUSE

INPUT

OUTPUT

MIN. LOAD 

4Ω

L

R

R-CH

R-CH

L-CH

R-CH

L-CH

L-CH

230 V~

50 Hz

6

7

8

9

10

11

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

       STA-400D: 270 W (RMS)

4 Ω

       STA-800D: 400 W (RMS)

       STA-400D: 180 W (RMS)

8 Ω

       STA-800D: 210 W (RMS)

       STA-400D: 180 W (RMS)

8 Ω

       STA-800D: 210 W (RMS)

       STA-400D: 45 W (RMS)

8 Ω

       STA-800D: 52,5 W (RMS)

       STA-400D: 45 W (RMS)

8 Ω

       STA-800D: 52,5 W (RMS)

       STA-400D: 45 W (RMS)

8 Ω

       STA-800D: 52,5 W (RMS)

       STA-400D: 45 W (RMS)

8 Ω

       STA-800D: 52,5 W (RMS)

       STA-400D:   90 W (RMS)

4 Ω

       STA-800D: 105 W (RMS)

       STA-400D:   90 W (RMS)

4 Ω

       STA-800D: 105 W (RMS)

       STA-400D: 67,5 W (RMS)

4 Ω

       STA-800D: 100 W (RMS)

       STA-400D: 67,5 W (RMS)

4 Ω

       STA-800D: 100 W (RMS)

       STA-400D: 67,5 W (RMS)

4 Ω

       STA-800D: 100 W (RMS)

       STA-400D: 67,5 W (RMS)

4 Ω

       STA-800D: 100 W (RMS)

6  Operation

Hint:

 To prevent switching noise, switch on the units 

connected to the amplifier before switching on the 
amplifier . After operation, switch off the amplifier be-
fore switching off the units connected .

1)  Before switching on the amplifier for the first 

time, set the two volume controls (2) to zero 
to make sure that the volume will not be 
too high .

2)  Use the POWER switch (5) to switch the am-

plifier on and off . The power LED ON (4) will 
light up a few seconds after switching on . 
This delay will prevent any switching noise .

3)  Use the volume controls (2) to adjust the de-

sired volume . In case of overload of a chan-
nel, the corresponding red LED CLIP (1) will 
light up . Turn back the control accordingly .

CAUTION

Never adjust a very high vol-
ume . Permanent high volumes 
may damage your hearing! 
Your ear will get accustomed

to high volumes which do not seem to be 
that high after some time . Therefore, do not 
further increase a high volume after getting 
used to it .

4)  In case of malfunction (overheating of am-

plifier or short circuit at a speaker terminal), 
the LED PROTECT (3) will light up and the 
amplifier will be muted . In this case, switch 
off the amplifier and consult skilled personnel 
for fault elimination .

7  Specifications

Model

STA-400D

STA-800D

Output power 
    at 4 Ω speaker 
    at 8 Ω speaker 
Peak output power

 
2 × 270 W

 

(RMS), 2 × 325 W max. 

2 × 180 W (RMS), 2 × 240 W max. 
       700 W

 
2 × 400 W (RMS), 2 × 470 W max. 
2 × 210 W (RMS), 2 × 270 W max. 
       1000 W

Input sensitivity for rated power 
Input impedance 
    XLR jacks 
    RCA jacks

1 V 

 

10 kΩ 

4.7 kΩ

Frequency range

20Hz – 20 kHz

S / N  ratio

< 110 dB, A-weighted

THD

< 0.02 %

< 0.004 %

Connections 
    signal inputs 
    speakers

 

XLR jacks, bal. and RCA jacks 

SPEAKON jacks and 4 mm jacks with screw terminals

Ambient temperature

0 – 40 °C

Power supply 
Max. power consumption

230  V/ 50 Hz 
600 VA

230  V/ 50 Hz 
920 VA

Dimensions (W × H × D) 
Weight

482 × 52 × 277 mm, 1 RS 
2.5 kg

482 × 52 × 298 mm, 1 RS 
3 kg

7.1 Pin configuration

XLR plug

1

2

3

= ground 
=  
= signal −

for balanced connection of audio units

SPEAKON plug

1−

2−

2+

1+

1+ and 2+ = positive pole 
1

 and 2

 = negative pole

for connection of speakers

Subject to technical modification .

All rights reserved by MONACOR 

®

 INTERNATIONAL GmbH & Co. KG. No part of this instruction manual 

may be reproduced in any form or by any means for any commercial use.

Summary of Contents for STA-400D

Page 1: ...ANLEITUNG INSTRUCTION MANUAL MODE D EMPLOI ISTRUZIONI PER L USO VEILIGHEIDSVOORSCHRIFTEN CONSEJOS DE SEGURIDAD RODKI BEZPIECZE STWA SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA Stereo...

Page 2: ......

Page 3: ...R SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS 3 Deutsch Seite 4 English Page 6 Fran ais Page 8 Italiano Pagina 10 Nederlands Pagina 12 Espa ol P gina 12 Polski Strona 13 Dansk...

Page 4: ...eine Sinusausgangsleistung be tr gt beim Anschluss von 4 Lautsprechern 2 270W STA 400D bzw 2 400W STA 800D Zwei temperaturgeregelte leise L fter sor gen f r die n tige K hlung des Verst rkers Der hohe...

Page 5: ...sehr hoch ein Hohe Lautst rken k nnen auf Dauer das Geh r sch digen Das Ohr gew hnt sich an gro e Lautst rken und empfindet sie nach einiger Zeit als nicht mehr so hoch Darum eine hohe Lautst rke nac...

Page 6: ...tal stereo PA amplifier class D is spe cially designed for applications on stage and in discoth ques When 4 speakers are con nected the RMS output power of the amplifier is 2 270W STA 400D or 2 400W S...

Page 7: ...ccordingly CAUTION Never adjust a very high vol ume Permanent high volumes may damage your hearing Your ear will get accustomed to high volumes which do not seem to be that high after some time Theref...

Page 8: ...AGE PAPIER TRIER 3 Possibilit s d utilisation Cet amplificateur st r o professionnel digital classe D est sp cialement con u pour une utilisa tion sur sc ne et en discoth que Avec des haut parleurs 4...

Page 9: ...mani re tr s lev e Un volume trop lev peut long terme g n rer des troubles de l audi tion L oreille s habitue des volumes lev s et ne les per oit plus comme tels au bout d un certain temps Nous vous...

Page 10: ...previsto specialmente per impieghi in spetta coli e discoteche Collegando degli altoparlanti di 4 la sua potenza efficace d uscita di 2 270W STA 400D e 2 400W STA 800D Due ventilatori silenziosi termo...

Page 11: ...re il volume desiderado con i rego latori volume 2 Se un canale sovrapilo tato si accende il relativo LED rosso CLIP 1 Quindi ridurre il regolatore in proporzione ATTENZIONE Mai tenere molto alto il v...

Page 12: ...anual de instrucciones protegido por el copyright de MONACOR INTERNATIONAL GmbH Co KG Toda reproducci n mismo parcial para fines comerciales est prohibida Het apparaat is in overeenstemming met alle r...

Page 13: ...nale y przeczyta uwa nie poni sz instrukcj obs ugi i zachowa tekst do wgl du Wi cej informacji dotycz cych obs ugi urz dzenia znajduje si w innych wer sjach j zykowych niniejszej instrukcji obs ugi ro...

Page 14: ...RNATIONAL GmbH Co KG Mit n t m n k ytt ohjeen osaa ei saa j ljent milt n osin k ytett v ksi mihink n kau pallisiin tarkoituksiin lta n Ge akt p s kerhetsinformationen innan enhe ten tas i bruk Skulle...

Page 15: ......

Page 16: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1555 99 02 05 2016...

Reviews: