IMER INTERNATIONAL S.p.A.
COMBI 200 VA
13
5HSDLUV
Repairs to the electrical installation must be performed exclusively by
specialised personnel. Use exclusively original IMER spare parts; modi-
¿FDWLRQVWRSDUWVDUHVWULFWO\SURKLELWHG7KHVSHFLDOGHVLJQRIWKH&RPEL
9$HQVXUHVWKDWQRRWKHUPDLQWHQDQFHRWKHUWKDQDVVSHFL¿HGDER
-
ve is required.
Ensure that the contacts of the power plug and plug-switch assembly
DUHHI¿FLHQW,IR[LGDWLRQLVGHWHFWHGFOHDQLPPHGLDWHO\
,QWKHHYHQWRIDFWLYDWLRQRIWKH5&&%FKHFNWKHPDFKLQH
DQG DUUDQJH IRU UHSDLUV LI QHFHVVDU\ H[FOXVLYHO\ E\ VSHFLDOLVHG
SHUVRQQHO
:DVWHGLVSRVDO
As regards disposal of processing waste observe all current legislation
in the country of use.
5(6,'8$/5,6.6$1'6$)(7<6,*16
Although the sawing machine has been manufactured fully in complian-
ce with current regulations, residual risks exist that cannot be eliminated
and involve the use of appropriate individual protection devices. Ade-
TXDWHZDUQLQJVLJQV¿WWHGRQWKHPDFKLQHSRLQWRXWERWKWKHULVNVDQG
the behaviour to be followed.
NOISE RISK
(DUSURWHFWLRQPXVWEHZRUQ
5,6.2),1-85<727+(+$1'6
6DIHW\JORYHVPXVWEHZRUQ
5,6.2),1-85<727+((<(6
(\HSURWHFWLRQPXVWEHZRUQ
$%1250$/86(5,6.
5HDGLQJWKHPDQXDOEHIRUHXVHLVFRPSXOVRU\
&XWWLQJZLWKZDWHULVFRPSXOVRU\
'$1*(52)&877,1*
'$1*(52)(/(&752&87,21
Please be reminded that checking the use of IPDs is delegated to the
employer.
7528%/(6+227,1*
&$87,21$OOPDLQWHQDQFHRSHUDWLRQVPXVWEHSHUIRUPHG
H[FOXVLYHO\ZLWKWKHPDFKLQHVZLWFKHGRIIZLWKWKHVHOHFWRUVHWWR
³´DQGWKHSRZHUSOXJGLVFRQQHFWHGIURPWKHPDLQV
Trouble
Causes
Remedies
The motor does not
start when the start
switch is pressed
Current does not reach
the supply line
Check the line *
The socket and plug
are not connected
properly
Restore correct
connection
The differential switch
is off
Turn the differential
switch on
The power cable from
the plug to the panel
is cut off
Change the cable *
An electric wire inside
the motor terminal strip
is cut off
Restore the connection *
An electric wire inside
the panel is cut off
Change the switch *
The start switch is
faulty
Change the switch *
Cooling water fails
to reach the blade
Low water level in tank
Restore the water level
3XPS¿OWHUFORJJHG
&OHDQWKHSXPS¿OWHU
Current fails to reach
the pump
Check the pump
electrical supply *
Pump failure
Change the pump *
The blade does
not cut
%ODGH¿WWHGLQWKH
opposite direction to
that of rotation
Remove the blade
and reposition it in the
direction shown on the
blade label
Worn blade
Change the blade
* Operation to be carried out by an electrician
GB