Operation
December 3, 2008
H A R R I S C O R P O R A TI O N
| I P A 68 0 0 + A S I O N I P V I D E O G A T EW A Y
Release 1.2.0 | Page 26
5.4.2 How to Extract Video from an IP Stream
Use this procedure to configure the to recover an ASI stream from an IP packet stream.
1
Specify the packet length for an ASI output.
Configuration/Decapsulator_1/ASI Pkt Len = (188,204)
2
Configure the input source.
Note:
If the source is providing a unicast then only the Port # (in the following steps) is required. The other parameters may be left ignored.
2a
Configure the source IP address and port (if necessary).
Configuration/Decapsulator_1/Source/…
Source IP = ###.###.###.###
– OR –
Multicast Group = ###.###.###.###
Port = (0–65535)
5.5 How to Monitor Module Alarms
’s Module Status LED illuminates red when an alarm condition is present.
Pilot and Navigator both can be configured to monitor an module. As such, the software aggregates alarm messages and presents
them in a manner that distinguishes between major and minor alarms. See the appropriate software control user manual or online help for more
information.