50
HUC6800
+
Installation and Operation Manual
Chapter 3: Operation
Module Status LEDs
The HUC6800
+
and HUC6800
+
C modules do not have any card-edge
alarms. Instead, module status LEDs on the corner of the module light
up if an error is detected. See
for the location of
these LEDs, and
for a definition of the LED colors.
Alarms are usually logged and monitored within software control
applications such as
+
PilotLite or CCS Pilot. See the appropriate
software control user manual or online help for more information.
Alarms
describes the specific alarms for HUC6800
+
and
HUC6800
+
C modules. You can only identify specific alarms using a
software control application.
Note
If the LED is flashing red,
please contact your customer
service representative.
Table 3-7.
LED Color and Meaning
LED Color
Sequence
Meaning
Off
There is no power to the module; the module is not
operational.
Green
There is power to the module; the module is operating
properly.
Red
There is an alarm condition.
Flashing Red
The module has detected a hardware/firmware fault.
Amber
The module is undergoing configuration.
Table 3-8.
HUC6800
+
Alarms
Alarm Name
Alarm Description
Alarm Level
SDI IP Video Present
Loss of SDI input video
Major
RefLockedAlarm
Loss of locked reference
Major
RefStdMismatch
Mismatch between reference
video and video standard
Major
Summary of Contents for Selenio 6800 HUC6800
Page 4: ......
Page 8: ...vi HUC6800 Installation and Operation Manual Contents...
Page 22: ...8 HUC6800 Installation and Operation Manual Chapter 1 Introduction...
Page 36: ...22 HUC6800 Installation and Operation Manual Chapter 2 Installation...
Page 70: ...56 HUC6800 Installation and Operation Manual Chapter 4 Specifications...
Page 82: ...68 HUC6800 Installation and Operation Manual Index...
Page 83: ......