36
HUC6800
+
Installation and Operation Manual
Chapter 3: Operation
Control Parameters
The following table lists all of the available parameters and options for
the HUC6800
+
and HUC6800
+
C. All parameters clip unless
otherwise indicated.
The On/Off combinations of the control LEDs on the card-edge indicate
the active bank number. See
“Changing Parameter Settings” on page 33
for more information.
Legend
Bold
option = Indicates that this is the default setting for the parameter
[RO] = Indicates that parameters are read-only/feedback, and cannot be
used to select controls
* = Indicates that this parameter wraps when controlled from the
card edge
Note
The sequence of options listed
in the
Options
column mirrors
the sequence achieved when
you move the Navigation
Toggle switch up.
Table 3-5.
Control Parameters
Bank,
Rotary
Switch
Parameter Name
Function
Options
X
Bank Select
Selects the active bank number
0
to 5
Bank 0
0, 1
Output Video Standard
Selects the SDI output video signal
standard (only the applicable options are
displayed in the OSD)
• 720p59.94
• 1080i59.94
• 720p50
• 1080i50
0, 2
On Screen Display
Turns on/off the on-screen display
• Off
• On
0, 3
OSD Transparency
Sets the on-screen display transparency
level
0
to 15
0, 4
Input Video Standard
Selects the SDI input video signal standard
(Note: If you select a non-synchronous
standard, the OSC will disappear; if this
occurs, use the LEDs to find Factory
Recall
and then regain use of the OSD.
This will take several seconds.)
• Auto
• 525
• 625
Summary of Contents for Selenio 6800 HUC6800
Page 4: ......
Page 8: ...vi HUC6800 Installation and Operation Manual Contents...
Page 22: ...8 HUC6800 Installation and Operation Manual Chapter 1 Introduction...
Page 36: ...22 HUC6800 Installation and Operation Manual Chapter 2 Installation...
Page 70: ...56 HUC6800 Installation and Operation Manual Chapter 4 Specifications...
Page 82: ...68 HUC6800 Installation and Operation Manual Index...
Page 83: ......