HUC6800
+
Installation and Operation Manual
35
Chapter 3: Operation
Cross-Functional Parameter Changes
When you configure certain parameters, changes are forced in other
associated parameters. For example, when
Horizontal Phase
is
controlled from the card edge, any wrap-around of the values will cause
a corresponding increment or decrement of the
Vertical Phase
value.
Table 3-4.
Cross-Functional Parameter Changes
Parameter Affected by
HD-SDI Output
Standard and Frame
Rate
HD-SDI Output Video Standard/Frame Rate
Parameter Name
720p/50 Hz
720p/59.94 Hz
1080i/50 Hz
1080i/59.94 Hz
Vertical Phase
0 to 749 lines
0 to 749 lines
0 to 1124 lines
0 to 1124 lines
Horizontal Phase
0 to 1979 pixels
0 to 1649 pixels 0 to 2639 pixels
0 to 2199 pixels
Vertical Scale
40–200%
33.75–200%
53.34–200%
45–200%
Horizontal Scale
56.25–200%
56.25–200%
37.50–200%
37.50–200%