IMAporter Reader with MobileAccess function
–
installation guide
20/24
The user ID is not authorized to enter - it is not configured in the connected control unit
6.2
Reader state signaling
–
Error states
When turned ON, the reader blinks red LED in 1sec interval
The reader has either not yet been configured using the configuration card or it is missing the system
settings that are to be set using the IMAporter Setup app.
Test if the reader is accepting RFID or NFC cards (e.g.: MIFARE Classic). If cards are accepted and the
reader is still blinking red LED, it is only missing the system settings using IMAporter Setup app. If it does
not accept cards at all, it is probably in default factory settings and needs to be configured.
Indication error during identification
–
the reader does not blink or beep
Check if the signalization wires are connected to the control unit and that the control unit is set properly.
LED and BEEPER are controlled by grounding the specific wires. If the reader is behaves in a “strange” way,
then the wires are probably not connected or controlled properly.
Identification using a mobile device is successful, but reader blinks red LED
The identifier assigned to the mobile device is probably not authorized to access. Please check settings in
the control unit.