12
MATRIX MANUAL 2014
I l l u s i o n - A u s t r a l i a n M a d e G a s L o g F i r e s
S.I.T GAS VALVE: MODEL 820 NOVA mV
6
5
4
3
2
1
9
IMPORTANT: IF THE APPLIANCE CANNOT BE ADJUSTED TO OPERATE CORRECTLY, CONTACT YOUR
SUPPLIER AND DO NOT OPERATE THE APPLIANCE UNTIL THE PROBLEM IS RECTIFIED.
PRESSURE TESTING:
ENSURE THE HEATER IS ISOLATED FROM THE GAS SUPPLY BY CLOSING THE MANUAL SHUTOFF VALVE DURING
ANY PRESSURE TESTING.
THE GAS VALVE REGULATOR CONTROLS MANIFOLD PRESSURE AND SHOULD BE CHECKED AT THE PRESSURE
TEST POINT. (SEE BELOW)
NOTE: BOTH INLET AND MANIFOLD PRESSURES SHOULD BE CHECKED USING THE VALVE PRESSURE PORTS ON
THE GAS VALVE.
PROCEDURE:
TURN VALVE TO “
OFF”
POSITION.
LOOSEN INLET PRESSURE POINT (5)
ATTACH MANOMETER TO INLET PRESSURE POINT (5)
LIGHT THE PILOT (SEE LIGHTING INSTRUCTIONS)
TURN VALVE TO
“ON”
(WITH THERMOSTAT ON “HIGH”
)
THE PRESSURE SETTING MUST BE WITHIN THE LIMITS SPECIFIED ON THE
COMPLIANCE PLATE LOCATED ON THE INSIDE OF THE CONTROL DOOR.
10
8
7
1. GAS COCK KNOB
2. HIGH LOW ADJUSTMENT
3. PILOT BURNER ADJUSTMENT
4. THERMOCOUPLE CONNECTION POINT
5. OUTLET PRESSURE POINT
6. INLET PRESSURE POINT
7. PILOT OUTLET
8. MAIN GAS OUTLET
9. MAIN GAS INLET
10. THERMO ELECTRIC SWITCH
PRESSURE TESTING