MATRIX  MANUAL 2014

I l l u s i o n - A u s t r a l i a n   M a d e   G a s   L o g   F i r e s

Suggested wall cut out sizes. (Suits Standard fascia & larger)

IMPORTANT: Allow min.

 

150mm up from floor when fitting standard window fascia 

and extra if skirting is fitted to the wall. 

Matrix MODEL

HEIGHT (Y) MIN

WIDTH (X) MIN

DEPTH (Z) MIN

GFX-S

780m

920mm

600mm

GFX-M

865mm

1020mm

600mm

GFX-L

950mm

1120mm

600mm

NOTE: The minimum width, depth and height 

shown in the table below relate to standard 

floor mounted fascia dimensions. 

 A more detailed dimension sheet is available 

from your dealer.

A1

C1

Minimum

Width

B1

All dimensions for the Illusion Matrix series of Gas Log Fires are correct at the time of printing. It is always advisable to check 
dimensions and clearances with your Illusion dealer before commencing  installation  thus avoiding potential problems during 
the installation. 

This appliance is certified only to be used with the specified flue system.

GFX-All Model  DIMENSIONS

ALL DIMENSIONS IN MILLIMETRES

External dimensions for all GFX Matrix Gas Log Fires  (All dimensions in millimetres)

Matrix MODEL

A

B1 & B2

C

D

E

F

G

H

I

GFX-S

945

B1=875 / B2=795

740

520

530

80

650

285

903

GFX-M

1045

B1=960 / B2=880

830

520

612

80

750

285

1003

GFX-L

1140

B1=1045 / B2=972

920

520

701

 80

850

285

1099

B1

A

WALL MOUNT FASCIA

SIDE VIEW REAR 

MOUNTED FLUE

E

I

G

H

TOP VIEW

 

TOP FLUE

 

D

SIDE VIEW TOP 

MOUNTED FLUE

C

F

 (WALL MOUNT FASCIA)

A

B2

FLOOR WALL MOUNT FASCIA

FLOOR

X

Y

Z

Summary of Contents for MATRIX GFX-L

Page 1: ...ve been tested and approved in accordance with Australian Standards for installation and operation as described in this manual and have been certified by SAI GLOBAL WARNING DO NOT MODIFY THIS APPLIANC...

Page 2: ...ce has been fully tested and approved to Australian Standards NOTE MATRIX GAS LOG FIRES MODELS GFX L GFX M AND GFX S ARE DESIGNED TO BE INSTALLED IN A SUITABLY CONSTRUCTED WALL OR FIREPLACE FACADE THE...

Page 3: ...ion Matrix series of Gas Log Fires are correct at the time of printing It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding...

Page 4: ...gas valve THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE WHEN THE APPLIANCE IS OPERATING 1 The flames appear excessively large and or sooting occurs on the logs 2 You can sm...

Page 5: ...fuel effect which is designed to operate with luminous flames and may exhibit slight carbon deposition PILOT FLAME IGNITION Depress and turn the control knob to the PILOT position Depress the button a...

Page 6: ...CONTACT WITH THE GLASS IF THE PRIMARY GUARD IS NOT FITTED ADDITIONALLY A SECONDARY FIRE SCREEN MAY BE APPROPRIATE WHEN SMALL CHILDREN OR THE INFIRM ARE IN THE VICINITY OF THE APPLIANCE WARNING DO NOT...

Page 7: ...AS NZS 5601 GAS INSTALLATIONS 2 Only an Authorised person should install the appliance 3 This appliance should be inspected prior to installation and the dealer contacted if any problems arise 4 This...

Page 8: ...127MM STAINLESS STEEL ACTIVE FLUE MUST BE USED FOR THE REAR FLUE MODEL GALVANISED STEEL MAY BE USED FOR ACTIVE FLUE ON THE VERTICAL FLUE MODEL MINIMUM OVERALL HEIGHT OF FLUE SYSTEM WHEN INSTALLED IS...

Page 9: ...M a d e G a s L o g F i r e s INSTALLATION OPTIONS 1 2 INTO FABRICATED ENCLOSURE VERTICALLY OR THROUGH REAR WALL AS 5601 AG 601 PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORIS...

Page 10: ...s L o g F i r e s INSTALLATION OPTION 3 AND 4 INTO EXISTING CHIMNEY VERTICALLY OR THROUGH REAR WALL OF CHIMNEY PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON IN ACCOR...

Page 11: ...og B GFX S onto the pins in the rear log and middle log as shown 7 Fit the left hand side top log onto the pins in the rear log and front lhs log as shown CHECK THE LOCATION OF ALL THE LOGS TO ENURE T...

Page 12: ...HE PRESSURE TEST POINT SEE BELOW NOTE BOTH INLET AND MANIFOLD PRESSURES SHOULD BE CHECKED USING THE VALVE PRESSURE PORTS ON THE GAS VALVE PROCEDURE TURN VALVE TO OFF POSITION LOOSEN INLET PRESSURE POI...

Page 13: ...ff the burner holes The logs should not have any sooting black areas If there is a problem call an authorised gas fitter or your local dealer 4 The appliance and flue system must be inspected by an au...

Page 14: ...RIX GFX L M S Spare Parts Spare parts are available from your supplier Refer to rear of this manual for contact details 1 2 3 4 5 6 1 Firebox body main 2 Fascia 3 Top grill assembly 4 Burner assembly...

Page 15: ...g F i r e s INSTALLATION OF FASCIAS TRIMS FLOOR MOUNT FASCIA The Wall mounted fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly attaching...

Page 16: ...L o g F i r e s INSTALLATION OF FASCIAS WALL MOUNT FASCIA The Floor mount fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly attaching 2 s...

Page 17: ...ergy saving method of operating the fan SHUT DOWN It will also shut down the fan 10 to 15 minutes after the heater is turned off once the firebox has cooled sufficiently REMOTE CONTROLLER OPTION The a...

Page 18: ...E CHANGED BY REMOVING THE REAR ACCESS COVER THE RECEIVER USES 4 AA BATTERIES WHICH CAN BE ACCESSED BY REMOVING THE SLIDING COVER ON THE REAR OF THE RECEIVER UNIT THE RECEIVER IS LOCATED ON THE RHS OF...

Page 19: ...ler SYMPTOM The logs have a build up of black soot in some areas POSSIBLE CAUSE Usually indicates incorrect positioning of logs if the unit has just been installed If the unit has been installed for s...

Page 20: ...Gippsland Hwy Dandenong Sth Victoria 3175 Australia Telephone 61 3 9793 7520 email service Illusionfires com au www Illusionfires com au Illusion Australia Pty Ltd reserves the right to alter specifi...

Reviews: