Draco tera
178
2017-09-06
The settings in the following menus have to be made globally and only
once within the Matrix Grid:
EXT Units, CPU Devices, CON Devices, User, CON Macros, User
Macros, CON Favorites, User Favorites, Virtual CPU Devices, Virtual
CON Devices
If global settings are made in the respective menus, they will be
immediately available on each matrix within the Matrix Grid.
General Preparation
The following requirements have to be fulfilled before starting the Matrix
Grid configuration:
1. The Matrix Grid function (Bundle 4) must be activated on all matrices
to be connected to the Grid by a license key (see Chapter 5.21,
Page 194).
2. Firmware V03.10 must be installed on all matrices to be connected to
the Grid.
3. All matrices to be connected to the Grid must be within the same
TCP/IP network (see Chapter 5.4.5, Page 93).
4. The port 5556 needed for network communication must not be
blocked by a firewall.