Operation
SNMP Module
90
The different modules can be expanded and collapsed by left-clicking on the “plus” and “minus” symbols in
the
Name
column.
By clicking on the “plus” and “minus” symbol in the upper right corner of the working area, you can expand
and collapse all module information with a click of the primary mouse button.
If a firmware update has failed, an error message and information appear in the update log in the lower
area of the work area.
Preparation
If the syslog function has not been set yet, we recommend activating the syslog function (see chapter 5.4.3,
page 40) before updating the firmware to log the update in case of update errors.
To be prepared for a firmware update, proceed as follows:
1. Save the device status configuration locally (see chapter 6.5, page 83).
2. If the options settings for the management software have not yet been set:
Open
Extras > Options
in the menu bar.
Under
Firmware Directory
insert in the directory from which the update files should be standardly
sourced.
3. Save the update files in the
Firmware Directory
.
Update
NOTICE
After the update, the extenders are automatically shut down and restarted with the updated firmware
without prior notice.
To update the extender firmware, proceed as follows:
1. Select
Status & Updates > Update - Extender Firmware
in the task area.
All updateable components of the extenders are automatically selected and highlighted in green.
2. Click the
Update
button in the lower part of the working area to start the update.
After the update, the extenders will automatically reboot with the updated firmware.