Technical Data
SNMP Module
96
7.3 Power Supply, Current Draw and Power Consumption
NOTICE
Overheating of the power supply units
In case of having redundant power supply units, the maximum current must not exceed the value of one
of the two power supply units due to the heat dissipation.
7.3.1 Power Supply of the Chassis (AC)
Product type
Maximum current draw Maximum voltage AC
Frequency
474-BODY6BP
1.300 mA
100 V bis 240 V
50/60 Hz
474-BODY6BPF
1.300 mA
100 V bis 240 V
50/60 Hz
474-BODY21/4U
4.000 mA
2x 100 V bis 240 V
50/60 Hz
7.3.2 Current Draw and Power Consumption of the SNMP Modules
NOTICE
Exceeding the maximum permissible current draw
In addition to the current draw of the extender and additional modules, there is also the current draw of
the connected peripherals.
Note the maximum current draw of the housing (see chapter 7.3.1, page 96).
Product type
Maximum current draw
Maximum power consumption
474-SNMP
300 mA
1,4 W
474-SNMPV3
510 mA
2,4 W
7.4 Environmental Conditions and Emissions
Parameter
Value
Operating temperature 5 to 45 °C (41 to 113 °F)
Storage temperature
-25 to 60 °C (-13 to 140 °F)
Relative humidity
Max. 80% non-condensing
Operating altitude
Max. 2.500 m (7,500 ft)
Sound pressure level
(SPL)
Max. 21 dBA per fan (474-6FAN)
Heat dissipation
Corresponds to power consumption in Watt (W)
7.5 Dimensions
Chassis
Dimension
Dimension of the shipping box
474-BODY6BP /
474-BODY6BPF
442 x 250 x 44 mm
(17.4" x 9.8" x 1.7")
550 x 372 x 155 mm
(21.7" x 14.6" x 6.1")
474-BODY21/4U
482 x 462 x 176 mm
(19.0" x 18.2" x 6.9")
645 x 574 x 368 mm
(25.4" x 22.6" x 14.5")