900861-00NC
23
IHP.us.com
When the fireplace is framed into position and the gas line is run in
place it is recommended to burn test the fireplace before the finish
work is complete. This will ensure proper operation and enables the
installer to check for any gas leaks at the fireplace.
NOTE: The pilot covers have a plastic film that must be removed
before installing.
Figure 31 - Pilot cover installed
ur
ne
r
Fireplace Side Wall
Pilot
Cover
Pilot
Cover
No media allowed
in shaded area
Figure 30 - Installing pilot cover
Fireplace Side Wall
Pilot Cover
Bu
rne
r
Burner E
nd
REMOVE PLASTIC FILM
FROM PILOT COVER
No media allowed
in shaded area
Once the burner pan assembly is secured into position, the pilot cov-
ers must be installed (one on each side). After you have removed the
plastic film install the pilot covers into the open slot of each burner
end (spacers that center the burner) with the open side of pilot cover
facing toward the fireplace side wall
(See Figures 30 and 31).
NOTE: Even though there is no pilot on the opposite end the other
pilot cover provides combustion air evenly to the burner for opera-
tion.
FINAL PREPARATION