900861-00NC
31
IHP.us.com
Error Codes
The control module has the ability to detect problems with the
valve kit system and will initiate error codes when they occur.
The error codes listed below will guide you to solving trouble-
shooting issues.
Ignition Safety Error:
One short beep every one second.
Cause: Pilot did not light within the trial period of 50-60 seconds
therefore step motor will turn gas valve to OFF position.
Corrective Action: Press OFF button to clear. Wait 30 seconds and
try again.
Recycle Safety Error:
Two short beeps every one second.
Cause: 1. Pilot automatically lights and drops out 3-times within
2-minutes causes step motor to turn gas valve to OFF position. 2.
Someone has pressed the ON/OFF button 6-times within 2-minutes
causing the step motor to turn gas valve to OFF position.
Corrective Action: Press OFF button to clear. After 5-minutes the
beeping will stop then retry.
ERROR CODE TROUBLESHOOTING
OPTIONAL ACCESSORIES
PRODUCT REFERENCE INFORMATION
Cat. No.
Model#
Description
F3502
LPK 1
LP Conversion kit for 36-inch outdoor fireplace
F3503
LPK 2
LP Conversion kit for 48-inch outdoor fireplace
F3504
LPK 3
LP Conversion kit for 60-inch outdoor fireplace
F3505
LPK 4
LP Conversion kit for 72-inch outdoor fireplace
F3507
GLO-BLACK
Black Onyx Glass Media, 5lb
F3508
GLO-CRYSTAL
Diamond Crystal Glass Media, 5lb
F3509
GLO-LT BLUE
Sapphire Blue Glass Media, 5lb
Remote Control Kit
Cat. No.
Model#
Description
F2687
EF-BRCK
Remote Control, Manual ON/OFF operation,
Off / Continuous pilot feature
ON
OFF
HI
LO
PILOT
Continuous
Sensor Safety Error:
Four short beeps every one second (constant
beeping).
Cause: Pilot flame sensor voltage too high, ground circuit not prop-
erly connected, pilot ground wire loose or not connected, or motor
not plugged into control module; therefore, step motor will turn gas
valve to OFF position.
Corrective Action: Press OFF button to clear. Wait 30-seconds to
thermocouple to cool down. If persist, then check other possible
causes and retry.
Thermal Safety:
Four short beeps every two seconds.
Cause: System has overheated and exceeded 170°F internal tem-
perature limit and the step motor will turn gas to OFF.
Corrective Action: Internal temperature must cool down to below
160°F then press the OFF button to clear and retry.
Communication Safety:
One short beep every four seconds.
Cause: Transmitter and module are not communicating properly.
Could be related to distance greater than 20-feet away from each
other or weak/dead batteries in one or the other.
Corrective Action: Module must receive a signal from transmitter.
Product Reference Information
Linear Electronic VF Outdoor Fireplaces
Cat. No.
Model
Description
F3442
BarcelonaLights36ZEN
Astria
®
, 36”, Natural Gas
F3443
BarcelonaLights48ZEN
Astria, 48”, Natural Gas
F3444
BarcelonaLights60ZEN
Astria, 60”, Natural Gas
F3445
BarcelonaLights72ZEN
Astria, 72”, Natural Gas
F3446
VRE4636ZEN
Superior
®
, 36”, Natural Gas
F3447
VRE4648ZEN
Superior, 48”, Natural Gas
F3448
VRE4660ZEN
Superior, 60”, Natural Gas
F3449
VRE4672ZEN
Superior, 72”, Natural Gas