MAINTENANCE
IC75 ENG
4-14
HYDRAULIC SYSTEM
Check the hydraulic oil level
1. Place the machine on a flat and rigid ground and bring
it into the posture for checking the hydraulic oil level.
Stop the engine.
2. Check the oil level gauge (1). If the oil level is between
H and L, it is proper.
The oil level differs with the oil temperature. The
following shows the standard.
•
Near the L level before starting operation
(Oil temperature: 10 to 30
°
C)
•
Near the H level during operation
(Oil temperature: 50 to 80
°
C)
3. If the oil level is below the L level, open the cover (2)
and refill hydraulic oil through the filler port (3).
Drain the hydraulic oil tank
WARNING
Oil is hot immediately after operation. You may get
burnt if you touch oil.
Start work after oil has cooled down.
1. Loosen the drain plug (4) under the hydraulic oil tank to
discharge water and sediment into the container.
2. Close the drain plug when clean hydraulic oil is only
discharged.
3. Check the hydraulic oil level. Refill oil if insufficient.
Level gauge
Posture for checking the
hydraulic oil level
Summary of Contents for IC75
Page 1: ...OPERATION MANUAL IC75 SERIAL NUMBER CA003001 PUB 1 1007...
Page 2: ......
Page 6: ...IC75 ENG...
Page 10: ...IC75 ENG...
Page 26: ...SAFETY IC75 ENG 1 16 This page is intentionally left blank...
Page 28: ...IC75 ENG...
Page 42: ...IC75 ENG...
Page 62: ...OPERATION IC75 ENG 3 20 This page is intentionally left blank...
Page 64: ...IC75 ENG...
Page 96: ...MAINTENANCE IC75 ENG 4 32 Electrical wiring system diagram INSTRUMENT PANEL...
Page 102: ...MAINTENANCE IC75 ENG 4 38 This page is intentionally left blank...
Page 103: ...IC75 ENG SPECIFICATIONS...
Page 104: ...IC75 ENG...