SmartModule CR2520
20
8 Parameter overview
8.1 General
Automatic saving of the communication and device parameters can be activated
or deactivated by means of the "save parameter" entry (see object directory, index
1010)�
When the value 0x02 is entered into SIdx 01, all parameters are automatically
saved if changes were made�
With the value 0x00 there is no automatic saving, i�e� changed parameters will only
be valid until the device is switched off or until the next reset is made�
With the function "restore" (see object directory , index 1011) the factory default
values can be restored (except for the baud rate and the node ID)� They become
valid with the next power on�
8.2 Manufacturer-specific profiles; index 2000 to 6FFF
Parameters
Index in object
directory
Default value
(factory set)
Change
saved auto-
matically
Change
effective
I/O configuration
2000
analogue inputs 0���10 V
binary inputs
binary outputs
adjustable
after PreOp
PWM frequency
Channel 16���18
2001
0xFA (250 Hz)
adjustable
after PreOp
PWM frequency
Channel 23���26
2010
0x64 (100 Hz)
adjustable
after PreOp
Node ID*
20F0, 20F1
0x20 (0d32)
yes
after reset
Baud rate*
baud rate*
0x04 (125 Kbits/s)
yes
after reset
Autostart
20F4
0x00 (deactivated)
*) The entries 20F0/20F1 and 20F2/20F3 must always contain identical values�
The new entries are valid after a reset (switching the module off/on)� Values
outside the permissible ranges will be rejected�