UK
SmartModule CR2520
31
Index
S-Idx
Name
Type
Default
Description
3
inhibit timer Trans PDO 1
rw
u16
0x0000
min� interval for transmission (in 100µs)
5
event timer Trans PDO 1
rw
u16
0x0000
max transfer break in trans type
"asynch" (0���65535ms)
when this time has elapsed the PDO is
transferred even if the appl� event has
not occurred
1801
0
highest numbered subindex
Transmit PDO 2
ro
u8
0x05
1
COB ID Transmit PDO 2
rw
u32
0x00000280
+ NodeID
PDO is valid (bit 31 = 0)
2
transmission type Trans PDO 2 rw
u8
0x01
0x01���0xF0 = synch cyclic
0xFE���0xFF = asynch (immediately)
3
inhibit timer Trans PDO 2
rw
u16
0x0000
min� interval for transmission (in 100µs)
5
event timer Trans PDO 2
rw
u16
0x0000
max transfer break in trans type
"asynch" (0���65535ms)
when this time has elapsed the PDO is
transferred even if the appl� event has
not occurred
1802
0
highest numbered subindex
Transmit PDO 3
ro
u8
0x05
1
COB ID Transmit PDO 3
rw
u32
0x00000380
+ NodeID
PDO is valid (bit 31 = 0)
2
transmission type Trans PDO 3 rw
u8
0x01
0x01���0xF0 = synch cyclic
0xFE���0xFF = asynch (immediately)
3
inhibit timer Trans PDO 3
rw
u16
0x0000
min� interval for transmission (in 100µs)
5
event timer Trans PDO 3
rw
u16
0x0000
max transfer break in trans type
"asynch" (0���65535ms)
when this time has elapsed the PDO is
transferred even if the appl� event has
not occurred
1803
0
highest numbered subindex
Transmit PDO 4
ro
u8
0x05
1
COB ID Transmit PDO 4
rw
u32
0x00000480
+ NodeID
PDO is valid (bit 31 = 0)
2
transmission type Trans PDO 4 rw
u8
0x01
0x01���0xF0 = synch cyclic
0xFE���0xFF = asynch (immediately)
3
inhibit timer Trans PDO 4
rw
u16
0x0000
min� interval for transmission (in 100µs)
5
event timer Trans PDO 4
rw
u16
0x0000
max transfer break in trans type
"asynch" (0���65535ms)
when this time has elapsed the PDO is
transferred even if the appl� event has
not occurred
1A00
0
number of application objects
linked with Trans PDO 1
rw
u8
0x01
1
1st mapping object Trans
PDO 1
rw
u32
0x10010061
index 6100, subindex 1, 16 bits