19
Writing of the data to the ID tag is effected in the same way by writing access to
the respective RPDO.
Data transfer per process data object is only possible in the "Operational"
operating status.
The preset TPDOs and RPDOs are allocated 64-bit data objects. For use
of 32-bit controllers, the settings of the PDOs must be adapted.
9.1.6 Object directory (OD)
CANopen communication (CiA 301)
Index
Subindex
Name
(object)
Type
Access
Default
value
capability
Save
object
value
0x1000
0x00
Device type
u32
ro
0x00000
000
-
-
0x1001
0x00
Error register
u8
ro
0x00
-
-
0x1003
0x01
0x02
Pre-defined error field
u32
ro
0x00000
000
-
-
0x1005
0x00
-ID SYNC
u32
rw
0x00000
000
-
yes
0x1008
0x00
Manufacturer device
name
vST
R
ro
Article
no. of
the de-
vice
-
-
0x1009
0x00
Manufacturer hard-
ware version
vST
R
ro
Current
hard-
ware
version
-
-
0x100A 0x00
Manufacturer software
version
vST
R
ro
Current
software
version
-
-
0x1010
0x01
Save parameters
(Save device parame-
ters in non-volatile
memory)
u32
rw
0x00000
000
-
-