UK
Process and dialogue module PDM360 NG-12
21
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!
18�04�2017
CR1200 / page 3
CR1200
Technical data
Control systems
Software/Programming
operating system
Embedded Linux 2�6
Programming system
CODESYS version 2�3 or CODESYS from version 3�5 SP8 (IEC 61131-3)
Graphic functions
via integrated target visualisation
Other features
Acoustic signal output
integrated buzzer, tone duration and pitch programmable
Temperature monitoring
2 integrated sensors for measuring the temperature inside the housing
Brightness adaptation
light sensor in the front of the device to adapt the brightness of the display and the
operating elements
Clock / battery
real-time clock (RTC), battery-buffered / CR2032 (3 V, 230 mAh)
Status LED
RGB LED, colours and states programmable by means of the application software
Operating states (preset)
Colour
Status
Description
–
permanently off no operating voltage
green
5 Hz
boot process application
2 Hz
application running (RUN) or set-up running
permanently on application has stopped (STOP) or no project
available
red
2 Hz
application is running with an error (RUN with
error)
permanently on system error (fatal error), device is in reset
(e�g� internal voltage error)
red/orange
2 Hz colour
change
overtemperature/undertemperature, device is
in reset until temperature in normal range
orange
5 Hz
boot process system recovery/update
2 Hz
system recovery/update running
briefl y on
system reset