Process and dialogue module PDM360 NG-12
16
Temporary connection: USB connector – USB device
► Use a connection cable with the designation "Full Speed/High Speed" (=
USB connection cable with twisted and screened cores)�
►
Do not make a connection using several USB connection cables�
►
Remove the connection cable after the programming or service works�
5.7.2 Short-circuit protection
NOTE
The USB interface (M12 connector) is not protected against short circuits with a
live wire outside the following voltage ranges:
–Data 0�3���3�6 V DC (3: pin 2)
+Data 0�3���3�6 V DC (3: pin 3)
ID
0�3���3�6 V DC (3: pin 4)
A short circuit will destruct the USB interface�
5.7.3 USB connection behind the service cover
►
Remove the service cover on the back of the unit�
(2 pcs� M3 socket head screws)
►
Connect the USB keyboard, mouse or memory stick with the USB interface�
►
Remove the USB devices after their use and close the service cover again�
1: service cover
2: USB socket, type A