UK
Process and dialogue module PDM360 NG-12
23
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!
18�04�2017
CR1200 / page 5
CR1200
Technical data
Control systems
Back of the unit
1
3
6
8
2
4
5
7
1: Service cover for USB connection, battery and watchdog reset
2: locator for the RAM
®
mount system
3: M12 connector (fig� shows max� number of connectors)
M12 connector
1
2, 5, 6, 7, 8
3
4
Connector
A-coded, 5 poles
Socket
A-coded, 5 poles
Socket
B-coded, 5 poles
Socket
D-coded, 4 poles
3
1
2
4
5
3
1
2
4
Wiring
(1) Supply, input/output
(2) CAN1
1
2
3
4
5
10���32 V DC (terminal 30) (IN)
IN
GND (terminal 31) (IN)
OUT
10���32 V DC (terminal 15) (IN)
1
2
3
4
5
screen
VBB
C
(OUT)
CAN1_GND (OUT)
CAN1_H
CAN1_L
(3) USB
(4) Ethernet
1
2
3
4
5
+5 V DC
-Data
+Data
ID
GND
1
2
3
4
TxD+
RxD+
TxD-
RxD-
housing = screen
(5) CAN2
(6) CAN3/4
1
2
3
4
5
screen
VBB
C
(OUT)
CAN2_GND (OUT)
CAN2_H
CAN2_L
1
2
3
4
5
CAN3_H
CAN3_L
CAN3/4_GND (OUT)
CAN4_H
CAN4_L
(7) analogue video input
(8) N/A
1
2
3
4
5
screen
GND (video 2)
GND (video 1)
FBAS1 (video 1)
FBAS2 (video 2)
1
2
3
4
5