5 Electrical connection
5.1 Connection accessories
You can find more information about the available accessories at:
www.ifm.com → Data sheet search → e.g. CR1200 → Accessories
or
www.ifm.com → Products → Accessories → Connection technology
5.2 General wiring information
Wiring of the M12 connectors
(→ 7 Technical data)
1: Supply, input/output
2: CAN1
3: USB
4: Ethernet
5: CAN2
6: CAN3/4
7: Analogue video input
8: N/A
M12 connectors (back of the unit)
NOTE
Wrong connection may cause damage to the device�
►
Observe the safety instructions�
NOTE
The short-circuit / reverse polarity protection of the device applies to the
operating voltage connections� A short circuit between operating voltage
(+24 V DC) and CAN_GND damage the device�
►
Basically all supply and signal cables must be laid separately�
►
Lay supply and signal cables away from the device using the shortest possible
route�
►
All connected cables must be provided with a strain relief�
5.2.1 Cover all unused connectors
NOTE
Moisture penetrating through unused or unprotected connectors may destroy the
device�
►
Cover unused connectors with protective caps�