background image

UK

Process and dialogue module PDM360 NG-12

27

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice!

18�04�2017

CR1201 / page 4

CR1201

Technical data

Control systems

Test standards and regulations

CE marking

EN 61000-6-2

Electromagnetic compatibility (EMC)

Immunity

EN 61000-6-4

Electromagnetic compatibility (EMC)

Emission standard

E1 marking

UN/ECE-R10

Emission standard

Immunity with 100 V/m

Analogue video input 30 V/m

Electrical tests

ISO 7637-2

Pulse 1, severity level: IV; function state C

Pulse 2a, severity level: IV; function state A

Pulse 2b, severity level: IV; function state C

Pulse 3a, severity level: IV; function state A

Pulse 3b, severity level: IV; function state A

Pulse 4, severity level: IV; function state A

Pulse 5, severity level: III; function state C

Data valid for the 24 V system

Climatic tests

EN 60068-2-30

Damp heat, cyclic

Upper temperature 55°C, number of cycles: 6

EN 60068-2-78

Damp heat, steady state

Test temperature 40°C / 93% RH,

Test duration: 21 days

EN 60068-2-52

Salt spray test

Severity level 3 (vehicle)

Mechanical tests

ISO 16750-3

Test VII; Vibration, random

Mounting location: vehicle body

EN 60068-2-6

Vibration, sinusoidal

10���500 Hz; 0�72 mm/10 g; 10 cycles/axis

ISO 16750-3

Bumps

30 g/6 ms; 24,000 shocks

Summary of Contents for CR1200

Page 1: ...Installation instructions Process and dialogue module PDM360 NG 12 CR1200 CR1201 80221591 00 04 2017 UK...

Page 2: ...with panel and surface mounting 9 4 2 3 Photoelectric sensor 9 4 2 4 Protective film for the touch screen CR1201 9 4 3 Panel mounting with installation kit 10 4 3 1 Panel cut out 10 4 3 2 Mounting ste...

Page 3: ...ance repair and disposal 29 8 1 Battery change 29 8 2 Cleaning the display surface 29 8 3 Cleaning the housing surface 30 8 4 Repair 30 8 5 Disposal 30 9 Approvals standards 30 This document is the or...

Page 4: ...rrect handling of the device Read this document before use to familiarise yourself with operating conditions installation and operation Keep this document during the entire duration of use of the devi...

Page 5: ...SELV as this voltage is supplied without further measures to the connected controller the sensors and the actuators The wiring of all signals in connection with the SELV circuit of the device must als...

Page 6: ...CANopen protocol For service purposes additional interfaces such as Ethernet USB or 3 further CAN interfaces are available Together with the Linux operating system they form a universal platform for n...

Page 7: ...programmable to IEC 61131 3 with target visualisation 32 bit controller and Embedded Linux operating system CAN interfaces with CANopen and SAE J 1939 protocol Ethernet and USB interfaces Multi functi...

Page 8: ...accessories at www ifm com Data sheet search e g CR1200 Accessories 4 2 General installation instructions 4 2 1 Locator for mounting accessories The back of the unit has been prepared for fixing the...

Page 9: ...2 4 Protective film for the touch screen CR1201 The unit is designed for use in harsh conditions in mobile machines Nevertheless the integrated glass touch screen cannot be used under all operating co...

Page 10: ...materials with a thickness from 1 to 10 mm The M5 hexagon nuts washers M5 set screws and adhesive damping strips are supplied with the installation kit Fixing profiles of the installation kit Dialogu...

Page 11: ...thickness Panel thickness Set screws 1 5 mm M5 x 35 5 10 mm M5 x 40 Insert the device into the cut out Screw the fixing profiles to the back of the device Tightening torque of the M5 hexagon nuts 5 0...

Page 12: ...ith mounted RAM mount system 4 4 1 Mounting steps Screw the mounting plate onto an even surface 38 1 5 56 62 6 38 1 30 5 3 Mounting plate with ball Hole dimensions Tightening torque 5 0 5 Nm Screw the...

Page 13: ...of the unit NOTE Wrong connection may cause damage to the device Observe the safety instructions NOTE The short circuit reverse polarity protection of the device applies to the operating voltage conne...

Page 14: ...h depends for example on the bus topology the selected operating mode 10 100 Mbits s or the quality of the connectors Use screened connector housings and connect the screen of the Ethernet cable to th...

Page 15: ...ces USB mouse keyboard and storage media e g USB memory stick 3 m USB connection via M12 connector 1 Dialogue module 2 USB connector for example in the control panel or in the dashboard 3 USB keyboard...

Page 16: ...ction NOTE The USB interface M12 connector is not protected against short circuits with a live wire outside the following voltage ranges Data 0 3 3 6 V DC 3 pin 2 Data 0 3 3 6 V DC 3 pin 3 ID 0 3 3 6...

Page 17: ...e them if necessary Internet protocol TCP IP IP address 192 168 82 xxx except for 247 s a Subnet mask 255 255 255 0 Gateway IP address 192 168 100 1 Switch on the operating voltage to the dialogue mod...

Page 18: ...ed documentation In addition to the CODESYS programming system the following documents are required for programming and set up of the device Programming manual CODESYS V2 3 alternatively as online hel...

Page 19: ...00 cd m typically 600 cd m adjustable 10 100 increments 1 Contrast ratio 500 1 typically 700 1 Character sets can be uploaded individually and is freely scalable preinstalled ifm ISO fonts with vehicl...

Page 20: ...S 401 version 1 4 or SAE J 1939 or free protocol Raw CAN max current load VBBC 400 mA protected by multi fuse Ethernet transmission rate 10 100 Mbits s USB 2 x USB 2 0 full speed transmission rate up...

Page 21: ...front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR2032 3 V 230 mAh Status LED RGB LED colours and states progr...

Page 22: ...nction state C Pulse 2a severity level IV function state A Pulse 2b severity level IV function state C Pulse 3a severity level IV function state A Pulse 3b severity level IV function state A Pulse 4 s...

Page 23: ...1 2 5 6 7 8 3 4 Connector A coded 5 poles Socket A coded 5 poles Socket B coded 5 poles Socket D coded 4 poles 3 1 2 4 5 3 1 2 4 Wiring 1 Supply input output 2 CAN1 1 2 3 4 5 10 32 V DC terminal 30 I...

Page 24: ...s 1 Contrast ratio 500 1 typically 700 1 Character sets can be uploaded individually and is freely scalable preinstalled ifm ISO fonts with vehicle speci c symbols Arial Courier Touch screen 5 wire re...

Page 25: ...DS 401 version 1 4 or SAE J 1939 or free protocol Raw CAN max current load VBBC 400 mA protected by multi fuse Ethernet transmission rate 10 100 Mbits s USB 2 x USB 2 0 full speed transmission rate up...

Page 26: ...front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery buffered CR2032 3 V 230 mAh Status LED RGB LED colours and states progra...

Page 27: ...unction state C Pulse 2a severity level IV function state A Pulse 2b severity level IV function state C Pulse 3a severity level IV function state A Pulse 3b severity level IV function state A Pulse 4...

Page 28: ...2 5 6 7 8 3 4 Connector A coded 5 poles Socket A coded 5 poles Socket B coded 5 poles Socket D coded 4 poles 3 1 2 4 5 3 1 2 4 Wiring 1 Supply input output 2 CAN1 1 2 3 4 5 10 32 V DC terminal 30 IN...

Page 29: ...ositive side up see marking on the cover Battery type 7 Technical data Disposal of used batteries 8 5 Disposal 8 2 Cleaning the display surface Unsuitable cleaning agents and chemicals can damage the...

Page 30: ...Observe the safety instructions 2 4 Tampering with the device 8 5 Disposal Dispose of used batteries in accordance with the national environmental regulations Do not dispose of used batteries with hou...

Reviews: