30
11 Operation
After power on, the unit is in the operating mode (= normal operating mode).
It carries out its measurement and evaluation functions and generates output
signals according to the set parameters.
►
Check whether the unit operates correctly.
11.1 Operating indicators
Table
11-1
[----] (continuous)
Initialisation phase after power on.
[numerical value] + LED 1 Current level in cm.
[numerical value] + LED 2 Current level in inch.
LED 8
Switching status OUT1 (lights when output 1 is switched).
[----]
Level below the active zone.
[FULL] + [numerical value]
alternately
The overflow prevention OP is reached (overflow warning) or
the level is above the active zone.
Adjustment [cOP] of the overflow prevention OP necessary.
[Loc]
Unit locked via buttons; parameter setting is not possible.
For unlocking press the two setting buttons for 10 s.
[uLoc]
Unit is unlocked / parameter setting is possible again.
[C.Loc]
The unit is temporarily locked. Parameter setting via IO-Link is
active (temporary locking).
[S.Loc]
Unit is permanently locked via software. This locking can only
be removed with a parameter setting software.
11.2 Read set parameters
►
Briefly press [Mode/Enter] (if required, repeat several times).
> Menu structure is scrolled until the required parameter has been reached.
►
Briefly press [Set].
> Respective parameter value is displayed for 30 s.