
24
10 Parameter setting
10.1 Parameter setting in general
1
Mode/Enter Set
►
Press [Mode/Enter] until the required
parameter is displayed.
To select parameters in the extended
menu (menu level 2):
►
Select [EF] and briefly press [Set].
2
Mode/Enter Set
►
Press and hold [Set].
> The current parameter value flashes
for 5 s.
> Value is increased* (step by step
by pressing the button once or
continuously by keeping the button
pressed).
3
Mode/Enter Set
►
Briefly press [Mode/Enter]
(= confirmation).
> The parameter is displayed again;
the new parameter value becomes
effective.
4
Change more parameters:
►
Start again with step 1.
Finish the parameter setting:
►
Wait for 30 s or press and hold
[Mode/Enter].
> The current measured value is
displayed.
►
Release [Mode/Enter],
> The parameter setting is finished.
*
)
Decrease the value: let the display move to the maximum setting value.
Then the cycle starts again at the minimum setting value.
Timeout
: If no button is pressed for 30 s during programming, the unit returns to the
operating mode with unchanged values (exception: cOP).
Lock / unlock:
The unit can be locked electronically to prevent unauthorised setting
(factory setting: not locked).
►
Make sure that the unit is in the normal operating mode.
To lock the unit:
►
Press both buttons simultaneously for 10 s.
> [Loc] is displayed.
To unlock the unit:
►
Press both buttons simultaneously for 10 s.
> [uLoc] is displayed.