Mounting
The inclination sensor is fastened to the mounting fixture by means of 4 M5xL
screws (conforming to DIN 7500 or DIN 7984) for levelling and detection.
To obtain precise measured values avoid mounting onto fixtures which vibrate
much and ensure a sufficient vibration decoupling if this is necessary.
When mounting ensure correct alignment of the inclination axes
(see housing imprint).
Longitudinal inclination = X axis (Trans PDO 1)
Transverse inclination
= Y axis (Trans PDO 2)
The indicated signs of the angle of inclination correspond to the factory default setting.
Electrical connection
Before commissioning the pins indicated above must be connected to the respec-
tive potentials.
To protect the whole system (wiring and sensor) the supply voltage must be
protected with max. 8 A.
To guarantee the electrical interference protection of the controller, the
housing must be connected to GND (e.g. to the ground of the vehicle).
In addition, the connection cable must be screened.
ENGLISH
INCLINATION SENSOR
CR2101
PAGE
25
+15°
-15°
X
+15°
-15°
Y
transverse inclination
longitudinal inclination
2
4
3
1
5
Designation
Pin
Potential
Operating voltage
1
GND
2
10...30 V DC
CAN interface
3
CAN_GND
4
CAN_H
5
CAN_L
mounting
surface