Hardware Operations
1230B0049701
2-20
The shape of expander board of SATAII&SAS backplane for 2.5” HDD is shown in the picture
below:
Figure 2-29 Expander Board Overview
3
rd
Party Connector
SAS Connector 4-7
Golden Finger
SAS Connector 0-3
SAS Connector 8-11
I
2
C (SMBus) Signal Connector
The location of SATAII&SAS backplane with expander board for 2.5” HDD is shown below:
Figure 2-30 Location of SATAII&SAS Backplane with Expander Board for 2.5” HDD
SATAII&SAS Backplane for 2.5” HDD
Expander Board
Reminder
Before you remove or install the SATAII&SAS backplane with expander board for 2.5” HDD,
please follow the steps below:
Step 1: Make sure the server is not turned on or connected to the AC power. To power off
the server, see “2.1.1 Power Off”.
Step 2: Remove the chassis cover. To remove the cover, see “2.2 Chassis Cover”.
Step 3: Remove the System Fan Assembly 1. To remove the System Fan Assembly 1, see
“2.6 System Fan Assemblies”.
Step 4: Disconnect all necessary cable connections.
For the expander board with expander chip, it only needs one input from SAS
daughter card. Only SAS connector 0-3 is necessary. SAS connector 4~7 and 8~11
are not needed for input.