6 - USE AND OPERATION
BOSS 332/545/551 E-volution
GB
6 - Pag. 3 / 19
The illustration shows the positions of both the electrical controls and hand-held keyboard "1".
2 MAIN SWITCH: turns the power supply on and off.
- Position 0 (OFF) the machine has no power supply.
- Position I (ON) the machine has power supply.
3 HALF-BUSHING OPENING AND CLOSING BUTTON (white light)
- During the "Manual" mode, when the bar feeder is in the required position, the half-
bushings will close when this button is pushed. If pushed again, the half-bushing will
open.
- During the "Automatic" mode, if pushed, the half-bushings will open and close, according
to the selected sequence. If pressed again, the half-bushings will remain open during the
entire operating cycle.
4 BAR FEEDER STOP BUTTON (red): to stop the bar feeder and to reset "Errors".
5 EMERGENCY STOP BUTTON: this button stops the bar feeder in an emergency situation. To
restart, first you must manually unlock the button
6 BAR FEEDER START BUTTON (green light): to start the bar feeder, hold down the button
until the button itself lights up.
7 REMNANT DETECTION DISABLING BUTTON (green light)
Press the button to feed a "new " bar without the detection of bar remnant in the bar pusher
collet.