5 - ADJUSTMENTS AND SETTING-UP
BOSS 332/545/551 E-volution
GB
5 - Pag. 25 / 33
5.3.2
Clamps - Replacement
Clamp replacement becomes necessary when the
new bars to be machined have a different profile
from the previously machined bars (e.g. when
changing over from round bars to square or
hexagonal bars). Contact IEMCA after-sales
service for more information.
Proceed as follows to replace the clamps:
• With the feeder powered off and the
compressed air supply disconnected, close the
clamps manually.
• Open the upper guides.
• Manually lift the lower lever and replace the
clamp. Remove the intermediate flag if
necessary (see paragraph 5.3.1).