GB
8 - TROUBLES - CAUSES - CURES
BOSS 332/545/551 E-volution
8 - Pag. 2 / 3
8.1
GENERAL FAULTS
TROUBLE
CAUSES
CURES
No power
Check the electric connections
Open guard
Close the guard
Emergency systems on
Disconnect the emergency devices
The bar feeder will not start
Motor thermal switch tripped
Reset the motor overload cut-out
with the special push-buttons.
The bar feeder has been reset
but the automatic cycle will not
start
No lathe signal
Check electric connection to the
lathe
The pneumatic devices will not
respond to controls
No air
Check the air system
The pre-feed and feed suddenly
stop
Motor thermal switch tripped
Reset the motor overload cut-out
with the special push-buttons
8.2
BAR MAGAZINE - Faults
PROBLEMS
CAUSES
REMEDIES
During the loading operation
the bar cannot be inserted into
the magazine
The bar contrast strips are
too low
Adjust the position of the contrast
strips
The first bar in the magazine
fails to drop into the guides
The bar contrast strips are
incorrectly adjusted
Adjust the bar contrast strips (see
chapter 5.3.3).