2 - TECHNICAL INFORMATION
BOSS 332/545/551 E-volution
GB
2 - Pag. 5 / 26
Clamps "D" close again to perform remnant "C"
extraction check.
If the remnant is still inserted in the bar-pusher
collet, the feeder stops; otherwise, it continues its
cycle.
Upper guides "H" open together with bar pusher
"A"; the bar selection device "F" moves upwards
thereby raising the first bar and withholding the
remaining bars. Bar "G" drips into the guide
channel.
Bar selection device "F" is lowered.
The small pusher truck "M" starts its stroke.