SETTING CHANGES
p.42
1.1
Date and Time
The LCD displays the current time. To change the time, press <ENT>, enter 15 Digits in a “YY
YYMMDDhmmssW” format, and then enter <ENT> again to confirm.
NOTE: For the days of the week (W),
1 : Sun, 2 : Mon, 3 : Tue, 4 : Wed, 5 : Thu, 6 : Fri, 7 : Sat.
e.g. To input August 24, 2009, 13:30:15, Monday,
enter 200908241330152.
1.2
Communication Address
A communication address (board ID or Communication ID) is a unique number assigned to e
ach device for communication. The default address is 00.
For proper communication with the PC, it is important that the value you set here should ma
tch the value you set on the application software. It is also important to make sure each devi
ce on a loop has a unique address.
To change the communication address of the iCON100, press <ENT>, enter the desired 2-Di
git address in the 00-31 range, and then press <ENT> again to confirm.
When you change DIP switch the changed address is displayed on LCD.
1.3
BAUD RATE