INSTALLATION OF THE PRODUCT
p.26
●
Connect COM port of Relay #1 to DC+12V
●
Connect NC port of Relay #1 to (+) wire of door lock device
●
Connect GND port to (-) wire of door lock devices
Door Lock (Power Fail Secure) Connection (Relay #1)
●
Connect COM port of Relay #1 to DC+12V
●
Connect NO port of Relay #1 to (+) wire of door lock device
●
Connect GND port to (-) wire of door lock devices
Alarm Device Connection (Relay #2)
●
Connect COM port of Relay #2 to DC+12V
●
Connect NO port of Relay #2 to (+) wire of Alarm devices
●
Connect GND port to (-) wire of Alarm devices
You need to connect the diode ( 1N4001 ~ 1N4007 or Similar) when connecting e
xternal devices to relay.
4.4
Reader Connections
Proximity Reader Connection