To adjust the integration time of the deviation measurement:
1.
Set the arrow of your mouse on the yellow triangle located to
the right of the "
User Time
" scale
2.
Stays clicked on your mouse and move the cursor up or down to
get the desired value. This value will be displayed to the right of
the cursor. (In the example above: 15 mn)
3.
Double click on the value
, it will be selected and you can
set the value desired from your digital keyboard.
The Displays of the MPX Guard:
The
MPX Guard
Plug-In has 3 horizontal display scales which allow you to control
with precision all the parameters.
MPX Attenuation:
This scale graded from
right to left
, indicates the
instantaneous rate of
attenuation
applied to the power by the
MPX Guard
. The value is displayed
digitally above and the red liner moves in real time from right to left to show you the
applied rate.
The
maximum point attained
by the line stays displayed by a red vertical bar. You
can, thus, leave the
MPX Guard
"in surveillance" mode and know the maximum
level of attenuation applied while you are away.
To
reset to
the red bar indicating the maximum value attained to zero click "
Reset
"
located to the right of the "
MPX Attenuation
" scale.
MPX Power Fast:
This scale indicates the power at the output of the
Processor
instantaneously. The
value is displayed digitally above and the yellow line moves in real time to indicate
the current value.
The
maximum point attained
by the line remains on display by a red vertical bar.
As a result you can let the "
MPX Guard
" watch over the signal and find the
maximum value obtained while you were away.
To
reset to zero
the red bar shows the maximum value attained then click on
"
Reset
" located to the right of the "
MPX Power Fast
" scale.
86
Summary of Contents for Digital Encoder Plus
Page 1: ...Digital Encoder Plus Rev 004 1 ...
Page 6: ...Di g i t a l En c o d e r Pl u s Audio Processor User Manual 6 ...
Page 23: ...Below the list of actions available for the Local Switches of the unit 23 ...
Page 75: ...To calibrate the processor click Next and the next screen will appear 75 ...
Page 77: ...The next 2 stages are similar but concern the TX2 77 ...
Page 96: ...96 Simplified bloc diagram of the DEP ...
Page 97: ...Examples of uses of DEP FM 97 ...