IDS 1632 Installer Manual   700-256-02K   Issued September 2009 

21 

 

Table 3 :  Location / Zone Defaults, Continued… 

 

Zone  Location  Sub-location 1 Default  Zone Type 

17 

17 

Disabled 

18 

18 

Disabled 

19 

19 

Disabled 

20 

20 

Disabled 

21 

21 

Disabled 

22 

22 

Disabled 

23 

23 

Disabled 

24 

24 

Disabled 

25 

25 

Disabled 

26 

26 

Disabled 

27 

27 

Disabled 

28 

28 

Disabled 

29 

29 

Disabled 

30 

30 

Disabled 

31 

31 

Disabled 

32 

32 

Disabled 

 
 

 

Table 4 provides  a complete list of the different zone types together  with a description of their 

characteristics. 

 

Table 4 : Programmable Zone Types 

 

Value 

Zone Type 

DISABLED 

A Zone violation of a disabled zone is ignored by the control panel and will not be indicated on 

the keypad. 

PRIMARY ENTRY / EXIT ZONE 

Violations of an Entry/Exit zone are ignored during the exit delay period of the arming 

procedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If valid User 

Code is not entered before the entry delay period expires, an alarm condition will be registered. 

Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm. 

 

This zone may also function as an entry/exit zone that is COMMON to two partitions. In such a 

case, should a user violate this zone and then disarm his partition, the OTHER partition will re-

arm after the entry delay. 

SECONDARY ENTRY / EXIT ZONE 

The secondary entry delay will be activated if this zone is violated when the panel is armed. 

FOLLOWER ZONE 

A violation of a Follower zone is ignored during the entry/exit delay period (this allows the user 

to enter/exit via the follower zone).  

A Follower zone will behave as an instant zone if the panel is armed and an entry/exit zone is 

not violated prior to violation of the follower zone. 

PANIC / PRIORITY ZONE 

Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the 

control panel to register a panic condition.  

This zone type CANNOT be bypassed. 

INSTANT ZONE 

When the panel is armed, the violation of an instant zone will cause the control panel to register 

an alarm condition. 

Summary of Contents for 1632

Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...

Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...

Page 3: ...ng a Faulty Keypad Device 15 4 2 Defaulting Keypads 15 5 Event Log 16 6 Download Code 16 6 1 Programming the Panel 16 6 2 Location Values 16 7 Programming the Panel 17 7 1 Entering Program Mode 18 7 2...

Page 4: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 4 14 Programmable Output Options 56 15 Keypad Options 58 16 Installer Options 59 Index of Programming Locations 60 Index 63...

Page 5: ...Figure 6 Fire Detect Output Sequence 34 Tables Table 1 Values Represented by each Zone LED 17 Table 2 Hexadecimal Value 18 Table 3 Location Zone Defaults 20 Table 4 Programmable Zone Types 21 Table 5...

Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...

Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...

Page 8: ...pany Control Room via a third party Communications Watchdog Company which monitors signal strength levels and ensures that reports are acknowledged Alarm Companies are also able to program upload down...

Page 9: ...rmined time Fax defeat answering machine override Dual reporting provides for duplicated reporting to two independent central base stations or one base station and a cellphone Dynamic battery self tes...

Page 10: ...e Zone Zone Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Zone Zone P 3K3 3K3 3K3 Connect as required with a resistor in unused zones Connect as required with a resistor in unused zones 3K3 3K3 Aux 1A S...

Page 11: ...by Zone Zone Doubling All zones must be end of line supervised Any unused zones must be terminated with a 3K3 resistor The end of line resistor must be placed inside or as close to the sensor as poss...

Page 12: ...e and its double will be violated 3 If the 12K resistor is open circuited the primary zone will indicate a violation i e assuming zone 8 is doubled in this case zone 8 will be indicated as violated 4...

Page 13: ...e receiver is connected to the communicator terminals marked phone and the incoming line to the terminals marked line 2 6 Programmable Outputs A relay board must be used when any device requiring a hi...

Page 14: ...and a value of 0 is entered into location 0 4 Enrolling Keypads and Other Devices A new panel supplied from the factory will have factory default values in all locations as indicated throughout this...

Page 15: ...can result in sluggish system behaviour Operation will become confusing Check After enrolling a keypad go to location 446 to check the keypad s ID which is a number that corresponds to the order that...

Page 16: ...of the order of 500 events 6 Download Code The download code in conjunction with the installer code is required for download access The default download code is 9999 Using the downloading software it...

Page 17: ...Zone LED Value Digit Zone 1 1 Units Zone 2 2 Zone 3 4 Zone 4 4 Zone 5 1 Tens Zone 6 2 Zone 7 4 Zone 8 8 Therefore the displayed value is 15 7 Programming the Panel For all programming procedures the...

Page 18: ...MBER of the program location you wish to view or change 3 Press the star key The READY indicator will continue flashing and the AWAY indicator will come on 4 The zone LED s will display the data store...

Page 19: ...selection of features has been finalised press the key to leave the location sub location with the state as indicated by the LED Example Location 40 allows the installer to select up to twelve fiftee...

Page 20: ...UST be performed when replacing a faulty device see Enrolling Keypads and Other Devices page 14 7 6 1 Zone Options LOCATIONS 1 32 Individual Zone Setup Sub location 1 Zone Type The first sub locations...

Page 21: ...red before the entry delay period expires an alarm condition will be registered Failure to exit through an Entry Exit zone after arming will cause the panel to Stay Arm This zone may also function as...

Page 22: ...en used as part of the cross zone matrix 14 PUSH TO ARM ZONE Violation of a push to arm zone during the exit delay will immediately arm the panel 15 OUTDOOR INSTANT ZONE When the panel is armed violat...

Page 23: ...mmed To disable a reporting code a double zero 00 must be entered If a zero is to be reported it must be entered as hexadecimal value A i e MODE 0 In the event that only 1 of the digits is programmed...

Page 24: ...ge 32 for a detailed description on Programming Programmable Outputs Sub location 12 Zone Name Editing Only with LCD keypads Zones may be given appropriate names like Front Door for zone 1 etc When th...

Page 25: ...on defines the cross zone delay timer period Value Response Time 0 3 seconds 1 10 seconds 2 15 seconds 3 20 seconds default 4 25 seconds 5 30 seconds 6 45 seconds 7 1 Minute LOCATION 37 Cross Zone Cou...

Page 26: ...ion 6 ON Enables keypad Fire Medical and Panic keys OFF Disables keypad Fire Medical and Panic keys 7 ON Enables the display of bypassed and stay zones when armed in the stay mode OFF Disables the dis...

Page 27: ...ough instantly displaying the trouble indication the panel will wait for this period of time before REPORTING the mains failure The same time period applies before the restoral event is reported and l...

Page 28: ...device trouble display 11 ON Enable bus trouble display OFF Disable bus trouble display 12 ON Enable Aux 12V trouble display OFF Disable Aux 12V trouble display 13 ON Reserved OFF Reserved 14 ON Enab...

Page 29: ...n an audible alarm is registered a delay can be implemented before the siren is triggered The alarm will however be reported as soon as it occurs Enable option 8 Location 38 Value Delay 0 3 seconds 1...

Page 30: ...location By default all codes are four digits in length The value programmed into this location has no effect on the download code which are always 4 digits in length Code Old four digit code New six...

Page 31: ...ng Code This code is reported when there is a tamper condition on any external device attached to the keypad bus LOCATION 57 Keypad Bus Failure Reporting Code This code is reported when there is a fau...

Page 32: ...rogrammed as Output Addressed 0 0 No Output Addressed 1 1 Panel Programmable Output 1 2 2 Panel Programmable Output 2 3 3 Panel Programmable Output 3 4 4 Panel Programmable Output 4 5 5 Panel Programm...

Page 33: ...ow Battery Programmable Output disabled 73 Battery Restore Programmable Output disabled 74 Auto Test Programmable Output disabled 75 Download Programmable Output disabled 76 Siren Trouble Programmable...

Page 34: ...ission This output follows the hook relay It may be used to trigger switching from the telephone line to a radio transmitter 10 System Clock Options LOCATION 98 System Time Enter the system time The f...

Page 35: ...aylight Saving is to commence If the last week of the month is wanted program a five 5 LOCATION 106 Month to Return to Standard Time Enter the month when Daylight Saving reverts back to standard time...

Page 36: ...d instantly regardless of any selected delay period LOCATION 111 Reporting Options LED On Off Action 1 ON Tone Dialling Enabled OFF Pulse Dialling Enabled 2 ON Join the telephone numbers together OFF...

Page 37: ...very thirteen days 14 Every fourteen days 15 Every fifteen days The value programmed into this location will determine the duration of time between Auto Tests LOCATION 113 Auto Test Time Enter the tim...

Page 38: ...el The voice tells the user what has happened on the panel For events that cause a voice report the Panel will call the relevant number Six seconds after it has dialled the last digit it will begin sp...

Page 39: ...137 Expansion Module Tamper Restore 3145 Keypad lockout 1137 RF Low Battery Restore 3384 Near Alarm Violation 1138 Close by User 3401 Tamper by Zone 1144 Close by Auto Arm 3403 Expansion Module Tamper...

Page 40: ...cated Pan Rest PR Zone Tamper BT Test Report TX Zone Tamper Restore BJ Download RB Zone Shutdown BB Duress HA Zone Shutdown Restore BU KP Panic PA AC Fail AT KP Fire FA Comms Fail YC KP Medical MA Lin...

Page 41: ...e Bypass Reporting Code OFF Disable Bypass Reporting Code 8 ON Enable Force Reporting Code OFF Disable Force Reporting Code 9 ON Enable Tamper Reporting Code OFF Disable Tamper Reporting Code 10 ON En...

Page 42: ...g Code OFF Disable 485 Device Tamper Reporting Code 7 ON Enable 485 Bus Tamper Reporting Code OFF Disable 485 Bus Tamper Reporting Code 8 ON Enable Box Tamper Reporting Code OFF Disable Box Tamper Rep...

Page 43: ...ions a value of 0 is used as a termination digit It is important therefore that any zeros 0 in the telephone number itself be entered as a 10 All hexadecimal values are entered using the mode key see...

Page 44: ...y telephone number A maximum of 24 digits can be entered Enter the digits consecutively and after the last digit has been entered terminate with a 0 11 3 Download Options LOCATION 123 Download Options...

Page 45: ...Number Storage Sub locations NOTE Locations 126 and 127 only apply to installations fitted with the IDS GSM Module Sub location 1 Airtime Number NOTE Only applicable to prepaid accounts this is the n...

Page 46: ...SIM cards Sub location 6 Cellphones to Report to 0 reports to no cellphones any other value 1 to 5 will allow enable reporting to be sent to that user s Cell Number AND all those user numbers precedi...

Page 47: ...remote 7 ON Enable Forced Arm OFF Disable Forced Arm 8 ON Enable Zone Bypassing OFF Disable Zone Bypassing 9 ON Enable Arm with Zones in the Entry Route Violated OFF Disable Arm with Zones in the Entr...

Page 48: ...OFF Disable Keypad Lockout 5 ON Enable User Phone Access OFF Disable User Phone Access 6 ON Enable Silent Keypad Panic OFF Disable Silent Keypad Panics Sub location 6 Exit Delay Period Value Time out...

Page 49: ...based on a 24 hour clock Example To auto arm at 11 35pm enter 2335 All four digits must be entered include any leading zeros 0100 for 1 am To disable this feature ensure that no day of the week is se...

Page 50: ...Keypad 9 2 Keypad 2 10 Keypad 10 3 Keypad 3 11 Keypad 11 4 Keypad 4 12 Keypad 12 5 Keypad 5 13 Keypad 13 6 Keypad 6 14 Keypad 14 7 Keypad 7 15 Keypad 15 8 Keypad 8 16 Keypad 16 Sub location 15 Keypads...

Page 51: ...rammable Output Disabled 23 Open Programmable Output 3 Set Low 1 24 Cancel Programmable Output Disabled 25 Alarm Restoral Programmable Output Disabled 26 Bypass Programmable Output Disabled 27 Forced...

Page 52: ...7 8 Panel Programmable Output 8 9 Wired Zone Expander 2 Programmable Output 2 10 Wired Zone Expander 2 Programmable Output 1 11 Wired Zone Expander 1 Programmable Output 2 12 Wired Zone Expander 1 Pro...

Page 53: ...er 38 298 User 163 174 User 39 299 User 164 175 User 40 300 User 165 176 User 41 301 User 166 177 User 42 302 User 167 178 User 43 303 User 168 179 User 44 304 User 169 180 User 45 305 User 170 181 Us...

Page 54: ...User 214 225 User 90 350 User 215 226 User 91 351 User 216 227 User 92 352 User 217 228 User 93 353 User 218 229 User 94 354 User 219 230 User 95 355 User 220 231 User 96 356 User 221 232 User 97 357...

Page 55: ...ation 2 User Code Properties This is a bitmapped sub location LED User Option 1 Master user 2 Duress code 3 Arm to disarm code maid s code 4 Group Arm 5 Group Disarm 6 Arm Code 7 Disarm Code 8 Report...

Page 56: ...etup the timing characteristics of each programmable output individually Location Output No Output Type 388 1 Panel Prog Output 1 389 2 Panel Prog Output 2 390 3 Panel Prog Output 3 391 4 Panel Prog O...

Page 57: ...ule ON Days This bitmapped sub location determines on which day s an output will be set LED Days of the Week 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday Sub location 4 Sched...

Page 58: ...ion 1 Keypad Partition Default Partition 1 Sub location 2 Keypad Options Change partitions by entering MODE Partition Number in USER MODE LED ON OFF Action 1 ON The Keypad will timeout back to its def...

Page 59: ...8 Keypad ID 13 Zone 20 Keypad ID 6 Zone 27 Keypad ID 14 Zone 19 Keypad ID 7 Zone 26 Keypad ID 15 Zone 18 Keypad ID 8 Zone 25 Keypad ID 16 Zone 17 16 Installer Options LOCATION 444 Reset Switch Disable...

Page 60: ...rouble Display 28 LOCATION 41 Siren Time Out Period 29 LOCATION 42 Siren Delay 29 LOCATION 43 Keypad Lockout Count Default 4 29 LOCATION 44 Keypad Lockout Time Default 30 seconds 30 LOCATION 45 Keypad...

Page 61: ...Cellphone Number 45 Sub location 3 SMS User 2 Cellphone Number 45 Sub location 4 SMS User 3 Cellphone Number 45 Sub location 5 SMS User 4 Cellphone Number 45 Sub location 6 SMS User 5 Cellphone Numbe...

Page 62: ...ting Code 55 Sub location 4 Stay Close Reporting Code 56 Sub location 5 Open Reporting Code 56 Sub location 6 Siren Cancel Reporting Code 56 LOCATIONS 388 399 Programmable Output Timing Setup 56 Sub l...

Page 63: ...7 B Battery Restore Reporting Code 31 Bitmapped Location 19 Box Tamper 13 Box Tamper Reporting Code 31 Bypass Reporting Code 23 C Call back Phone Number 45 Cellphone Number Storage Sub locations 45 Ce...

Page 64: ...Follower Zone 21 Follower Entry Zone 22 Force Arm Explanation 47 Force Arm Reporting Code 23 Function Driven Programmable Outputs 33 G Global Options 26 Group Reporting Code Enable Disable 41 GSM Mod...

Page 65: ...s P Panic Priority Zone 21 Partition Arm Options 47 Partition Options 48 Partition Programmable Outputs 51 Partition Reporting Codes Explanation 50 Partition Setup 46 Partition Zone Allocation 46 Peri...

Page 66: ...tup 47 Secondary Communicator Format 38 Secondary Entry Delay 49 Secondary Entry Exit Zone 21 SIA Reporting Codes 40 Silent Zone 23 SIM Card PIN Number 45 Siren Cancel Reporting Code 56 Siren Delay 29...

Page 67: ...cations 44 Telephone Numbers Programming 43 Transformer 8 Trouble Display 28 U User Code Properties 55 User Reporting Codes 55 V View Keypad 59 W Warning Zone 22 Wiring 10 Z Zone Doubling 12 Zone Name...

Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...

Reviews: