IDS 1632 Installer Manual 700-256-02K Issued September 2009
21
Table 3 : Location / Zone Defaults, Continued…
Zone Location Sub-location 1 Default Zone Type
17
17
0
Disabled
18
18
0
Disabled
19
19
0
Disabled
20
20
0
Disabled
21
21
0
Disabled
22
22
0
Disabled
23
23
0
Disabled
24
24
0
Disabled
25
25
0
Disabled
26
26
0
Disabled
27
27
0
Disabled
28
28
0
Disabled
29
29
0
Disabled
30
30
0
Disabled
31
31
0
Disabled
32
32
0
Disabled
Table 4 provides a complete list of the different zone types together with a description of their
characteristics.
Table 4 : Programmable Zone Types
Value
Zone Type
0
DISABLED
A Zone violation of a disabled zone is ignored by the control panel and will not be indicated on
the keypad.
1
PRIMARY ENTRY / EXIT ZONE
Violations of an Entry/Exit zone are ignored during the exit delay period of the arming
procedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If valid User
Code is not entered before the entry delay period expires, an alarm condition will be registered.
Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm.
This zone may also function as an entry/exit zone that is COMMON to two partitions. In such a
case, should a user violate this zone and then disarm his partition, the OTHER partition will re-
arm after the entry delay.
8
SECONDARY ENTRY / EXIT ZONE
The secondary entry delay will be activated if this zone is violated when the panel is armed.
2
FOLLOWER ZONE
A violation of a Follower zone is ignored during the entry/exit delay period (this allows the user
to enter/exit via the follower zone).
A Follower zone will behave as an instant zone if the panel is armed and an entry/exit zone is
not violated prior to violation of the follower zone.
3
PANIC / PRIORITY ZONE
Regardless of whether the panel is armed or not, a violation of a Priority zone will cause the
control panel to register a panic condition.
This zone type CANNOT be bypassed.
4
INSTANT ZONE
When the panel is armed, the violation of an instant zone will cause the control panel to register
an alarm condition.
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...