IDS 1632 Installer Manual 700-256-02K Issued September 2009
36
11. Communicator Options
LOCATION 110
Communication Delay
Value
Delay
0
3 seconds
1
10 seconds
2
15 seconds
3
20 seconds
4
25 seconds
5
30 seconds
6
45 seconds
7
1 minute
8
2 minutes
9
3 minutes
10
4 minutes
11
5 minutes
12
10 minutes
13
15 minutes
14
18 minutes
15
21 minutes
If delayed communications is enabled for either partition - (See locations 128 to 135 for Partition Setup)
the panel will wait for this period before reporting zone violations and restorals. If the alarm is cancelled
within this time zone, violations and restorals will not be reported. Violations will however be logged in the
event log. Panic events will be reported instantly – regardless of any selected delay period.
LOCATION 111
Reporting Options
LED
On / Off
Action
1
ON
Tone Dialling Enabled
OFF
Pulse Dialling Enabled
2
ON
Join the telephone numbers together
OFF
Keep two separate telephone numbers
3
ON
Enable Dual Reporting
OFF
Disable Dual Reporting
Single reporting options (LED 3 off)
4
ON
Reports to secondary number only after failing on attempting the
primary number.
(Panic event initiates dual reporting)
OFF
Alternates reporting attempts between both numbers until
successful with one of them.
(Single reporting, regardless of panic)
NOTE:
The panel may be programmed to report to a single central station (single reporting) or to report
to 2 central stations (dual reporting).
When programmed for single reporting, the panel default will alternate attempts between the two
“equally ranked” stored numbers. With LED 4 on, the secondary number will only be called if the
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...