Sub-location 9
Swinger Shutdown Reporting Code
The swinger shutdown zone code will be reported if the system is armed and a zone is automatically
bypassed as a result of multiple violations of that zone.
Sub-location 10
Swinger Shutdown Restore Reporting Code
If enabled, this code will be reported when a swinger shutdown zone is automatically restored i.e. un-
bypassed.
Sub-location 11
Zone Programmable Output Location
A programmable output will be pulsed or latched, high or low if a zone causes an alarm condition. If
pulsed, the output will be pulsed for the time programmed in Sub-location 1 of Locations 388 - 399.
Two digits must be programmed for each zone. The first digit references the programmable
output number e.g. output 1 to 5 (7 with an expander). The second digit sets the output action. Refer
“System Programmable Outputs” (Page 32) for a detailed description on Programming Programmable
Outputs.
Sub-location 12
Zone Name Editing (Only with LCD keypads)
Zones may be given appropriate names, like “Front Door” for zone 1, etc. When the zone is triggered, the
display will indicate “Front Door”, instead of “Zone 1”. (Full instructions are included in the LCD keypad
manual.)
7.6.2 System Options
LOCATION 33
Zone Shutdown Count (Default = 5)
Determines the number of times a zone may be violated during an arm cycle before it is automatically
bypassed. Select zones individually for this option in locations 1 – 32s (Sub-location 2). Valid range of
data for this location is 1 to 15.
LOCATION 34
Programmable Zone Loop Response Time
Value Response Time Value Response Time
0
6 ms
8
96 ms
1
12 ms
9
108 ms (default)
2
24 ms
10
120 ms
3
36 ms
11
132 ms
4
48 ms
12
144 ms
5
60 ms
13
156 ms
6
72 ms
14
168 ms
7
48 ms
15
180 ms
The zone loop response is the period of time for which the programmed zone must remain violated
before a violation is registered. Unless the Second Loop Response Time is selected, this location will
determine the response time.
Summary of Contents for 1632
Page 1: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 1...
Page 2: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 2...
Page 6: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 6...
Page 7: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 7...
Page 68: ...IDS 1632 Installer Manual 700 256 02K Issued September 2009 68...